_WE Design Your Tomorrow . . ._ 

## MEMORANDUM 

TO: Davis Ray FROM: Larry Green, PE, PTOE DATE: February 28, 2024 

SUBJECT: Wynnefield Properties, Town of Boone – Traffic & Site Access Assessment 

The Wynnefield Properties development is proposed from one full movement site access driveway on New Market Boulevard (across from an existing Ford Dealership) in the Town of Bone. A total of 60 Senior Apartment Units is proposed for the site.  Based upon the Institute of Transportation Engineer’s (ITE) Trip Generation Manual, 11[th] Edition, a total of 198 Daily Trips, 12 AM Peak Hour Trips, and 15 PM Peak Hour Trips will be generated by the site. 

The purpose of this memorandum is to respond to requirements contained in the Town of Boone Unified Development Ordinance (UDO) Subsection 4.04.02 with regards to traffic and site access design assessments. Shown below are issues and responses: 

1. A Traffic Impact Analysis (TIA) may be required if the development proposes an access to the public road system within 100’ of the STOP bar of any traffic control signal; or 

Response: Access is located more than 100 feet from the STOP bar at any traffic signal. 

2. A TIA may be required if the development proposes an access to the public road system within 200’ of the STOP bar of any traffic control signal and based upon Institute of Transportation Engineers (ITE) trip generation rates is projected to generate eighty (80) or more exiting trips during any one (1) hour period of any day; or 

Response: Access is located more than 200 feet from STOP bar at any traffic signal and the site will not generate 80 or more trips during any one (1) hour period of the day. 

3. A TIA may be required if the development proposes to have access to any public road at a location where sight distance in any direction along the road is less than 500’; or 

Response: Wetherill Engineering conducted a sight distance field measurement at the proposed site access point on New Market Boulevard.  The results of the sight distance measurement revealed that 530 feet of sight distance is available looking to the right along New Market Boulevard (looking south on New Market Boulevard); and that 430 feet of 

Office: 919.851.8077 Fax: 919.851.8107 

1223 Jones Franklin Rd. Raleigh, NC  27606 

www.wetherilleng.com 

Updated: 06/28/2019 Version 1.1 

**Packet Pg. 99**
{1}------------------------------------------------
Transportation Planning Bridge/Structural **Offices in** Civil/Site **Raleigh & Charlotte** Construction Observation Surveying 

_WE Design Your Tomorrow . . ._ 

sight distance is available looking to the left along New Market Boulevard (looking north on New Market Boulevard).  The posted speed limit on New Market Boulevard at the site access driveway is 25 MPH.  Based upon AASHTO’s A Policy on Geometric Design of Highways and Streets criteria, a total of 280 feet of sight distance is required to safely turn from a STOP controlled intersection.  As noted from the field measurements, available sight distances from the proposed driveway location far exceed the required AASHTO criteria. 

4. A TIA may be required if the development proposes access onto a public road that does not have a paved width of at least eighteen feet (18’); or 

Response: The approximate width of New Market Boulevard at the site access driveway is 33 feet. 

5. A TIA may be required if the development proposes access to a public road that currently operates at a level of service of D or less and based upon ITE trip generation rates is projected to generate 1,500 weekday trips. 

Response: As noted above, the proposed site will generate 198 weekday trips, and therefore, the level of service criteria is not applicable. 

## **Conclusion** 

Based upon the trip generation and site access design elements of the proposed 60 Senior Apartment Units on New Market Boulevard in the Town of Boone, a formal TIA should not be required based upon subsection 4.04.02 of the Town of Boone Unified Development Ordinance. 