{0}------------------------------------------------
Exhibit 3 <u>QUALLS BUILDING - TENANT UPFITS</u> 



CONTACT 



ARTISTIC RENDERING 



ARTISTIC RENDERING 



ARTISTIC RENDERING 



ARTISTIC RENDERING 

##### **Sheet Index** 

**Cover Sheet, Site Plans, Permit Requirements** 

A001 Cover Sheet and Site Plan A002 Historical References Survey A003 Existing Lower Level Plan A004 Existing Main Level Plan A005 Existing Upper Level Plan A006 Demolition Main Level Plan A007 Demolition Upper Level Plan A008 Schedules **Plans - App Sportwear** A111 App Sportwear Floor Plan A112 App Sportwear - Life Safety Plan A113 Sections **Elevations** A201 Elevations **Plans - Venture** 1.101 Venture Lower Level Plan 1.102 Venture Floor Plans 1.103 Venture - Life Safety Plan 1.104 Sections 

##### **<u>Property Information</u>** 

Project Type: Interior renovations at 595 and 605 West King St. Owners: Trade Land Company  Will & Josh Clark Site Address: 595-605 W. King St Boone NC 28607 Assessor Parcel Number: 2900884900000 

Zoning: B1 WITH HISTORIC DISTRICT OVERLAY 

##### **<u>General Notes</u>** 

1. All work shall conform to all applicable codes and ordinances. 

2. Do not scale drawings: use calculated dimensions only. Verify existing "as-built" dimensions as req'd. All dimensions are to face of stud unless noted otherwise. 

3. Verify all rough-in dimensions and locations for equipment, fixtures etc. Provide all blocking, buck-outs, backing and jacks required for installation. 

4. All wood in contact with concrete to be pressure treated. 

5. All flashing to be galvanized, galvalume or factory finish to be approved by architect and owner. 

6. Contractor shall verify all existing conditions prior to initiating any portion of the work. 

7. Provide all protection, shoring and bracing as required by site conditions in order to maintain a safe job site and protect components to remain. 

8. Stair and guardrail openings to be less than 4". 

9. Tight line all affected drainage to approved drainage system. 

10. All framing to be properly caulked, sealed, gasketed or otherwise treated to minimize air infiltration prior to sheathing and finishing. 

11. All (new) smoke detectors to be hardwired to home's electrical system. 

12. If subsurface water is encountered at any point, contact the owner's geotechnical engineer for recommendations before proceeding. 

QUALLS BUILDING 595, 597,601, 605 W. KING ST. 

**^** <u>North</u> 

Adrian Tait PO Box 1926 Blowing Rock, NC 28607 adrian@sketchlinearchitecture.com 828-545-1323 

SEALS 



DISCLAIMER Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. 

PROJECT 

230403 

**QUALLS BUILDING - TENANT UPFITS** 

CLIENT 

Trade Land Company Will & Josh Clark 3675 Marine Dr Greenville, NC 27834 

NOTES 

02/19/2024 - HPC Approval 

REVISION BY DATE COMMENT 

SHEET NAME 

**Cover Sheet and Site Plan** 

SHEET NUMBER 

**A001** 

1 OF 12 

605 W King St Vicinity Map 

DRAWN BY Adrian Tait 

PLOTTED 2/15/2024 

**Packet Pg. 167**
{1}------------------------------------------------
SEALS DISCLAIMER Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. PROJECT **QUALLS BUILDING - TENANT UPFITS** 



<!-- Start of picture text -->
+22'-0"<br>3 Roof<br>+12'-0"<br>2 Upper Level<br>±0"<br>1 M i L l<br>3<br>Primary Elevation (Existing)<br>A201 0 4' 8' 16'<br>SCALE: 1/8"   =    1'-0"<br><!-- End of picture text -->



<!-- Start of picture text -->
BRICKWORK<br>CLEAN AND REPOINT MORTAR<br>AS NEEDED<br>+22'-0"<br>3 Roof<br>+12'-0"<br>4'-5 7/8"'-5 7/8"5 7/8"" 4'-5 3/4"'-5 3/4"5 3/4"" 4'-0"'-0"0"" 4'-0 1/8"'-0 1/8"0 1/8"" 5'-11 1/8"'-11 1/8"11 1/8"" 5'-0 3/8"'-0 3/8"0 3/8"" 5'-0"'-0"0"" 5'-2 1/2"'-2 1/2"2 1/2"" 6'-0 5/8"'-0 5/8"0 5/8"" 5'-11 7/8"'-11 7/8"11 7/8""<br>2 Upper Level<br>ee<br>2'-8" CONFIRM HEIGHT AFTER<br>REMOVAL OF AWNING<br>NEW INSULATED GLASS<br>WINDOWS AND DOUBLE<br>DOOR WITH BLACK<br>FRAMES<br>EXISTING BRICK<br>WINDOW BASE TO<br>REMAIN<br>+ An! Lg ±0"<br>| L___}| \\| ] {—__ Vt i 1 Main Level e<br>288 '-""<br><!-- End of picture text -->



<!-- Start of picture text -->
NEW TRANSOM WINDOWS ABOVE  +12'-0"<br>4'-5 7/8"'-5 7/8"5 7/8"" 4'-5 3/4"'-5 3/4"5 3/4"" 4'-0"'-0"0"" 4'-0 1/8"'-0 1/8"0 1/8"" 5'-11 1/8"'-11 1/8"11 1/8"" 5'-0 3/8"'-0 3/8"0 3/8"" 5'-0"'-0"0"" 5'-2 1/2"'-2 1/2"2 1/2"" 6'-0 5/8"'-0 5/8"0 5/8"" 5'-11 7/8"'-11 7/8"11 7/8""<br>STOREFRONT OPENING. BLACK ALUMINUM 2 Upper Level<br>FRAME WITH DARK TINTED GLASS<br>2'-8" CONFIRM HEIGHT AFTER<br>REMOVAL OF AWNING<br>NEW INSULATED GLASS<br>WINDOWS AND DOUBLE<br>NEW GLASS STOREFRONTS WITH<br>DOOR WITH BLACK<br>DOUBLE DOORS, INSULATED GLASS AND<br>FRAMES<br>BLACK FRAMES<br>EXISTING BRICK<br>REPLACE EXISTING DOOR PANEL WITH NEW<br>WINDOW BASE TO<br>FULL-LITE PANEL WITH BLACK FRAME<br>REMAIN<br>+ An! Lg ±0"<br>| L___}| \\| ] {—__ Vt i 1 Main Level e<br>4<br>Primary Elevation (New)<br>A201 0 2' 4' 8'<br>SCALE: 1/4"   =    1'-0"<br>2d<br>BRICKWORK<br>CLEAN AND REPOINT MORTAR<br>AS NEEDED<br>+22'-0"<br>/ , 3 Roof<br>W1  W2  W3<br>SILLS<br>+12'-0"<br>INSPECT WINDO W SILLS TO<br>NEW WOOD WINDOW S =e ENSURE WEATH ERTIGHT 4 2 Upper Level<br>PROPOSED NEW DOOR INTO<br>TENANT SPACE TO UTILIZE EXISTING  PROPOSED NEW EXIT DOOR<br>WINDOW OPENING AT FORMER LOCATION<br>PROPOSED NEW WOOD WINDOW<br>TO UTILIZE EXISTING DOOR<br>W4  W5<br>OPENING<br>D11<br>5 PROPOSED NEW ELEVATED<br>DECK AND EXIT STAIRS<br>D12<br>INFILL BRICKWORK TO MATCH<br>EXISTING<br>±0"<br>1 Main Level<br>PROPOSED NEW ELEVATED<br>DECK AND EXIT STAIRS, BLACK<br>METAL FRAME, STAIRS, RAILING<br>LLL Ha aan<br>EXISTING ELECTRICAL PANELS<br>-9'-0"<br>CNA -1 Lower Level<br>11' 0"<br>2 Rear Elevation<br>288 '-""<br><!-- End of picture text -->



CONTACT 

Adrian Tait PO Box 1926 Blowing Rock, NC 28607 adrian@sketchlinearchitecture.com 828-545-1323 

DISCLAIMER Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. 

PROJECT 230403 **QUALLS BUILDING - TENANT UPFITS** 

CLIENT 

Trade Land Company Will & Josh Clark 3675 Marine Dr Greenville, NC 27834 

NOTES 

02/19/2024 - HPC Approval REVISION BY DATE COMMENT 

SHEET NAME 

###### **Elevations** 

12 OF 12 

SHEET NUMBER 

**A201** 

2 

<u>East Elevation</u> 

<u>1</u> 

A201 SCALE: 1/4"   =    1'-0" 

<u>0</u> 

<u>2'</u> 

<u>8'</u> 

<u>4'</u> 

A201 

<u>0</u> 2' 4' 

<u>8'</u> 

DRAWN BY 

Adrian Tait 

SCALE: 1/4"   =    1'-0" 

PLOTTED 2/15/2024 **Packet Pg. 168**