{0}------------------------------------------------
**==> picture [254 x 54] intentionally omitted <==**

**----- Start of picture text -----**<br>
FRONT PERSPECTIVE<br>1 OPTION 2<br>7<br>**----- End of picture text -----**<br>


## **PRELIMINARY DESIGN** 

## **THALER MIXED USE** 

3/6/24 

~~**Packet Pg. 25**~~ 

APPALACHIAN ARCHITECTURE, P.A.
{1}------------------------------------------------
**==> picture [722 x 511] intentionally omitted <==**

**----- Start of picture text -----**<br>
EXISTING BUILDING<br>EASEMENT / CORRIDOR<br>SPRINKLER ELECT. ELEV.<br>DN<br>UP<br>RETAIL SPACE<br>2,878 S.F.<br>EXISTING BUILDING<br>1 FIRST FLOOR PLAN<br>1  3/32" = 1'-0"<br>PRELIMINARY DESIGN<br>THALER MIXED USE<br>Packet Pg. 26<br>APPALACHIAN ARCHITECTURE, P.A.  3/6/24<br>Communication: 174 S. Depot St - Option 2 - Renderings and Elevations  (174 S. Depot Street -<br>**----- End of picture text -----**<br>
{2}------------------------------------------------
**==> picture [722 x 532] intentionally omitted <==**

**----- Start of picture text -----**<br>
EXISTING BUILDING<br>WH W/D REF DW<br>UNIT #1<br>(1-BEDROOM<br>665 S.F.) UNIT #2<br>BEDRO O M MECH . (2-BEDROOM BEDROOM #1<br>11'-6"x13'-0" 1013 S.F.) WH W/D 11'-0"x17'-8"<br>ELEVATOR<br>BEDROOM #2<br>DN 9'-7"x13'-3"<br>DW<br>DW<br>BEDROOM BEDROOM #2<br>11' -2 " x13 '-0" 9'-7"x13'-3"<br>WH W/D<br>UNIT #4 UNIT #3 WH W/D<br>BEDROOM #1<br>(1-BEDROOM (2-BEDROOM<br>11'-5"x17'-8"<br>798 S.F.) 985 S.F.)<br>EXISTING BUILDING<br>1 SECOND FLOOR<br>2  3/32" = 1'-0"<br>PRELIMINARY DESIGN<br>THALER MIXED USE<br>Packet Pg. 27<br>APPALACHIAN ARCHITECTURE, P.A.  3/6/24<br>DW<br>R<br>EF<br>BALCONY<br>BALCONY<br>MECH.<br>REF<br>REF<br>BALCONY MECH.<br>MECH.<br>BALCONY<br>Communication: 174 S. Depot St - Option 2 - Renderings and Elevations  (174 S. Depot Street -<br>**----- End of picture text -----**<br>
{3}------------------------------------------------
**==> picture [582 x 283] intentionally omitted <==**

**----- Start of picture text -----**<br>
SECOND FLOOR<br>13' - 4"<br>FIRST FLOOR<br>0' - 0"<br>1 FRONT ELEVATION<br>3  3/32" = 1'-0"<br>**----- End of picture text -----**<br>


**PRELIMINARY DESIGN THALER MIXED USE** 

APPALACHIAN ARCHITECTURE, P.A. 

~~**Packet Pg. 28**~~ 3/6/24
{4}------------------------------------------------
**==> picture [760 x 579] intentionally omitted <==**

**----- Start of picture text -----**<br>
EXISTING BUILDING<br>1 RIGHT SIDE ELEVATION<br>4  3/32" = 1'-0"<br>PRELIMINARY DESIGN<br>THALER MIXED USE<br>Packet Pg. 29<br>APPALACHIAN ARCHITECTURE, P.A.  3/6/24<br>t - Option 2 - Renderings and Elevations  (174 S. Depot Street -<br>S<br>Communication: 174 S. Depot<br>**----- End of picture text -----**<br>
{5}------------------------------------------------
**==> picture [89 x 109] intentionally omitted <==**

**----- Start of picture text -----**<br>
SECOND FLOOR<br>13' - 4"<br>FIRST FLOOR<br>0' - 0"<br>**----- End of picture text -----**<br>


1 REAR ELEVATION 5 3/32" = 1'-0" ~~Oo~~ 

**PRELIMINARY DESIGN THALER MIXED USE** 

APPALACHIAN ARCHITECTURE, P.A. 

~~**Packet Pg. 30**~~ 3/6/24
{6}------------------------------------------------
**==> picture [710 x 208] intentionally omitted <==**

**----- Start of picture text -----**<br>
EXISTING BUILDING<br>**----- End of picture text -----**<br>


1 LEFT SIDE ELEVATION 6 3/32" = 1'-0" 

APPALACHIAN ARCHITECTURE, P.A. 

**PRELIMINARY DESIGN THALER MIXED USE** ~~**Packet Pg. 31**~~ 3/6/24