{0}------------------------------------------------
## **SECTION A DETAILS** 

## **FACILITY INFORMATION [Detailed discussion of any items in Section A]** 

BorgWarner Turbo Systems (BWTS), a division of the global automotive supplier BorgWarner, Inc., manufactures commercial vehicle turbochargers.  The facility also plays the role of research and development center for the company’s North American operations. 

In their turbocharger production operations, the facility utilizes three diesel-fired internal combustion engine test cells, one of which (AEC-4) has the capability to test turbochargers on gasoline engines. Each test cell is essentially a metal frame that allows for the mounting of a diesel engine.  With an engine mounted, the facility conducts dynamometric testing of the engine with a turbocharger that has been specifically designed for that engine model.  Once the facility has fine-tuned the turbocharger to achieve the desired performance specifications for that engine model, the turbocharger can begin mass production.  The pollutants of concern are from diesel combustion and include carbon monoxide (CO), nitrogen oxides (NOX), particulate matter (PM, PM10, PM2.5), sulfur dioxide (SO2), volatile organic compounds (VOCs), and various hazardous air pollutants (HAPs) and toxic air pollutants (TAPs). 

In their turbocharger production operations, the facility also utilizes seven natural gas-fired turbocharger test cells.  Each turbocharger test cell is essentially a metal frame that allows for the mounting of a turbocharger to a small natural gas-fired burner.  With a turbocharger mounted, the facility conducts endurance testing of the turbocharger with the natural gas-fired burner supplying simulated engine exhaust gases.  The pollutants of concern are the result of natural gas combustion and include CO, NOX, PM, PM10, PM2.5, SO2, VOCs, and various HAPs and TAPs. 

BWTS also had a remanufacturing operation (Reman) where used turbochargers received from customers are disassembled, the scrap material is separated out, and the salvageable components are reprocessed.  PM generated by the various machining processes in Reman is routed to a Torit dust collection system, which is exhausted outdoors.  The pollutants of concern are PM, PM10, PM2.5, and a few metal HAPs and TAPs. This operation no longer exists and has been removed from the permit. 

The facility processes wastewater from various operations, including building cleaning and maintenance, using a natural gas-fired thermal oxidizer (TO-2) to evaporate the wastewater.  Pollutants from this operation are the result of natural gas combustion and wastewater solids, including PM, PM10, , PM2.5, VOCs, and various HAPs and TAPs. 

The facility has been regulated as a Title V source due to potential emissions exceeding 100 tons per year for NOx and CO emissions related to the engine test cells (AEC1-4). The facility has elected not to take a Title V limit on these sources. They have taken a toxics limit that keeps their actual emissions below Title V thresholds. 

General Conditions and the list of insignificant activities will be updated as part of this renewal. The facility has requested modifications to AEC-1 and AEC-4,diesel-fired internal combustion engine test cells that can now also be used to test natural-gas fired combustion engines. AEC-3 was a diesel-fired internal combustion engine test cell that has now been decommissioned and will be removed from the permit. For the insignificant sources, the eight natural gas-fired turbocharger test cells, AGS-1 through AGS-8, are now grouped together for a combined maximum capacity of 24 MMBtu/hr. ES-118 which included various parts washers has been removed from the facility and will be removed from the permit. ES-125 and ES126 were added as insignificant activities. In addition, BorgWarner Turbo Systems requested to change their name to BorgWarner Emissions, Thermal & Turbo Systems. The permit application fee was received on August 27, 2024. 

The Agency received comments from EPA regarding the draft permit. The recommended changes were minor and mainly involved some references in the permit that needed to be updated. A full list of those changes can be found in the permit review folder for this permit under EPA Review Notes.
{1}------------------------------------------------
## **SECTION B DETAILS** 

## **APPLICATION INFORMATION** 

**[List all emission sources (permitted and exempt) reviewed as a result of this application, their associated control devices and pollutants.  Provide a detailed discussion of any other items in Section B at bottom under “Application Notes”]** 

|**SECTION B DETAILS**|**SECTION B DETAILS**|**SECTION B DETAILS**|**SECTION B DETAILS**|
|---|---|---|---|
|**APPLICATION INFORMATION**<br>**[List all emission sources (permitted and exempt) reviewed as a result of this application, their**<br>**associated control devices and pollutants.  Provide a detailed discussion of any other items in**<br>**Section B at bottom under“Application Notes”] **||||
|**Emission**<br>**Source ID**|**Emission Source Description**<br>**1.**<br>**Type, manufacturer, capacity**<br>**2.**<br>**Control device with ID(ifany)**|**Pollutant(s)**<br>**Emitted**|**Miscellaneous Notes**|
|AEC-1|One (1) diesel-fired internal<br>combustion engine test cell for<br>engines with a maximum output<br>rating of 1,500 horsepower that<br>can also be used to test natural-<br>gas fired internal combustion<br>engines with a maximum output<br>rating of 516 horsepower.|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e||
|AEC-2|One (1) diesel-fired internal<br>combustion engine test cell for<br>engines with a maximum output<br>rating of 1,500 horsepower|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e||
|AEC-4|One (1) diesel-fired internal<br>combustion engine test cell for<br>engines with a maximum output<br>rating of 1,500 horsepower that<br>can also be used to test gasoline-<br>fired internal combustion engines<br>with a maximum output rating of<br>375 horsepower and natural-gas<br>fired internal combustion engines<br>with a maximum output rating of<br>516 horsepower.|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e||
|TO-2|One (1) 2.50 million BTU per hour<br>natural gas-fired thermal oxidizer|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e|RGF Environmental Systems, Inc.<br>This oxidizer processes mop<br>water and has a capacity of 150<br>gallons per hour|
|The following equipment meets the definition of insignificant activity pursuant to the AB Air Quality Code<br>17.0503– “Definitions.”||||
|IC-1|One (1) 150-kilowatt (225<br>horsepower) Cummins natural<br>gas-fired emergency generator|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e|Model GGLB.  Although exempt<br>from permitting, this generator will<br>be included as a permitted source<br>so that the relevant requirements<br>of NSPS Subpart JJJJ can be<br>included in the permit.|
|IC-2|One (1) 35-kilowatt (68<br>horsepower) Generac natural gas-<br>fired emergency generator|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e|Model 3434650100.  Although<br>exempt from permitting, this<br>generator will be included as a<br>permitted source so that the<br>relevant requirements of MACT<br>Subpart ZZZZ can be included in<br>the permit.|
|IC-3|One (1) 175-horsepower Clarke<br>diesel-fired fire pump|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>CO2e|Model JU6H-UFM0.  The engine<br>was manufactured by John<br>Deere.  Although exempt from<br>permitting, this fire pump will be<br>included as a permitted source so<br>that the relevant requirements of<br>NSPS Subpart IIII can be included<br>in the permit.|
{2}------------------------------------------------
|ES-120|One (1) 1,000-gallon aboveground<br>gasoline storage tank|VOC, HAP, TAP|Although exempt from permitting,<br>this tank will be included as a<br>permitted source so that the<br>relevant requirements of MACT<br>Subpart CCCCCC can be<br>included in the permit.|
|---|---|---|---|
|ES-110|Eight (8) natural gas-fired<br>turbocharger test cells:<br>Combined maximum capacity of<br>24 MMBtu/hr.|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e|These units were previously listed<br>as AGS-1-8, but are now listed as<br>one unit with a combined<br>maximum capacity for flexibility.<br>These units are considered an<br>insignificant activity because of<br>size or production rate as defined<br>in AB Air Quality Code 17.0503 –<br>“Definitions.”|
|ES-111|One (1) 6,000-gallon aboveground<br>diesel storage tank|VOC, HAP, TAP|This unit is considered an<br>insignificant activity because of<br>size or production rate as defined<br>in AB Air Quality Code 17.0503 –<br>“Definitions.”|
|ES-113|One (1) Shaft and Wheel Washer<br>utilizing a 1.03 million BTU per<br>hour natural gas-fired burner|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e|This unit is considered an<br>insignificant activity because of<br>size or production rate as defined<br>in AB Air Quality Code 17.0503 –<br>“Definitions.”|
|ES-119|One (1) Landa Pressure Washer<br>utilizing one (1) 0.95 million BTU<br>per hour natural gas-fired burner|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e|This unit is considered an<br>insignificant activity because of<br>size or production rate as defined<br>in AB Air Quality Code 17.0503 –<br>“Definitions.”|
|ES-121|One (1) 250-gallon aboveground<br>diesel storage tank.|VOC, HAP, TAP|This unit is considered an<br>insignificant activity because of<br>size or production rate as defined<br>in AB Air Quality Code 17.0503 –<br>“Definitions.”|
|ES-122|Three (3) Hydrotron DHYD Series<br>wet collector downdraft<br>workstations|PM, PM10, PM2.5|The facility requested that this<br>source be removed from the<br>Insignificant Activity list because<br>they are PM emission sources<br>that vent indoors. Per AB Air<br>Quality Code 17.0508(i)(13),<br>fugitive emission sources do not<br>need to be included in Title V<br>permits unless they are subject to<br>regulation. This source will be<br>removed from the permit during<br>this renewal.|
|ES-123|One (1) QA/QC Laboratory|VOC, HAP, TAP|This unit is considered an<br>insignificant activity because of<br>size or production rate as defined<br>in AB Air Quality Code 17.0503 –<br>“Definitions.”|
|ES-124|One (1) boiler utilizing a 1.999<br>million BTU per hour natural gas-<br>fired burner|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e|This was an off-permit change.<br>Borg Warner notified us in an<br>email on October 5, 2016.|