{0}------------------------------------------------
|ES-125|One (1) Fan Drive Assembly<br>Operation|VOC|This operation consists of a ink jet<br>printer, a machining coolant<br>operation, and a coil<br>encapsulating operation. This<br>equipment was previously located<br>at the Fletcher plant and was re-<br>located to this facility in December<br>of 2021.|
|---|---|---|---|
|ES-126|One (1) Molding Operation|VOC|Nylon injection molding operation.<br>This equipment was previously<br>located at the Fletcher plant and<br>was re-located to this facility in<br>December of 2021.|
|NA|Various oil mist eliminators that<br>vent indoors (including units on<br>five plasma welders and a high-<br>speed core balancer in the testing<br>lab)|PM, PM10,<br>PM2.5, VOC,<br>HAP, TAP|The facility requested that this<br>source be removed from the<br>Insignificant Activity list because<br>they are PM emission sources<br>that vent indoors. Per AB Air<br>Quality Code 17.0508(i)(13),<br>fugitive emission sources do not<br>need to be included in Title V<br>permits unless they are subject to<br>regulation. This source was<br>removed from the permit during<br>the previous renewal in 2019.|
|NA|Various natural gas-fired space<br>heaters|CO, NOX, PM,<br>PM10, PM2.5,<br>SO2, VOC, HAP,<br>TAP, CO2e|The facility requested that this<br>source be removed from the<br>Insignificant Activity list because<br>they are considered insignificant<br>because of category, and thus are<br>not required to be included in at<br>Title V permit per AB Air Quality<br>Code 17.0507(b). This source<br>was removed from the permit<br>during the previous renewal in<br>2019.|



## **APPLICATION NOTES** 

As part of the permit renewal application, the insignificant activities have been updated.
{1}------------------------------------------------
## **SECTION C DETAILS** 

## **REGULATORY INFORMATION** 

**(Identify the AB Air Quality Regulations reviewed because of this application.  At a minimum, the regulations already listed should be reviewed and reason given for applicability or nonapplicability.  If a regulation has a standard, list the standard and indicate how the source is in compliance.)** 

|**SECTION C DETAILS**|**SECTION C DETAILS**|**SECTION C DETAILS**|
|---|---|---|
|**REGULATORY INFORMATION**<br>**(Identify the AB Air Quality Regulations reviewed because of this application.  At a minimum, the**<br>**regulations already listed should be reviewed and reason given for applicability or non-**<br>**applicability.  If a regulation has a standard, list the standard and indicate how the source is in**<br>**compliance.)**|||
|**AB Air Quality Regulation Number /**<br>**Title**|**Emission**<br>**Source ID**<br>**No(s). Subject**|**Notes on Regulation**<br>(Compliance demonstration, applicability, etc.)|
|17.0500 – Title V Procedures|Facility-Wide|The facility has been regulated as a Title V source<br>due to potential emissions exceeding 100 tons per<br>year for NOx and CO emissions related to the engine<br>test cells (AEC1-4). Previously, the facility had also<br>been subject to Title V permitting procedures because<br>the former vibration damper operation had potential<br>emissions in excess of the 100-ton per year<br>applicability threshold for VOCs, the 25-ton per year<br>applicability threshold for combined HAPs, and the 10-<br>ton per year applicability threshold for individual<br>HAPs. The vibration damper operation has been<br>removed and the facility no longer exceeds major<br>source thresholds for combined and single HAPs.<br>Although maximum emissions (with the PSD<br>avoidance limit) are now below all Title V permitting<br>thresholds, the facility wishes to retain its Title V<br>permit and has not taken a limit to stay below TV<br>thresholds.|
|17.0700 – Toxic Air Pollutant Procedures|Facility-Wide|The facility was subject to a toxics evaluation in 2010<br>because of a modification to combustion source AEC-<br>4. This resulted in a diesel usage limitation of 74,000<br>gallons per year for AEC-1, AEC-2, and AEC-4, so<br>that all TAP emissions would be below the TPERs<br>(see file for Permit No. 11-773-09A). This limit was<br>modified in 2020 to 68,500, which included adding a<br>boiler and changing the rating of the AGS test cells.<br>For this permit renewal, in order to stay below the<br>TPERs for all TAP emissions, a diesel usage limitation<br>of 67,000 gallons per year for AEC-1, AEC-2, and<br>AEC-4 will replace the previous limitation. This was<br>due to the addition of burning natural gas in AEC-1<br>and AEC-4. This includes the change in the rating of<br>theAGS test cells.|
|4.0524 – New Source Performance<br>Standards (40 CFR 60, Subpart IIII)|IC-3|This emergency-use fire pump is subject to the<br>requirements of 40 CFR Part 60, Subpart IIII –<br>“Standards of Performance for Stationary<br>Compression Ignition Internal Combustion Engines,”<br>which requires that the engine meets the emission<br>limits listed in the subpart.  The fire pump must be<br>equipped with a non-resettable hour meter (if the<br>engine does not meet the standards applicable to<br>non-emergency engines) and nonemergency use<br>(e.g., testing) is limited to 100 hours per year.  Ultra-<br>low sulfur diesel (ULSD) fuel must be used.  See the<br>notes below for additional information.|
|4.0524 – New Source Performance<br>Standards (40 CFR 60, Subpart JJJJ)|IC-1|This emergency-use generator is subject to the<br>requirements of 40 CFR Part 60, Subpart JJJJ –<br>“Standards of Performance for Stationary Spark<br>Ignition Internal Combustion Engines,” which requires<br>that the generator meets the emission limits listed in<br>the subpart.  Nonemergency use (e.g., testing) is<br>limited to 100 hours per year.  Because the engine<br>was built before January 1, 2011, a non-resettable<br>hour meter is not required.  See the notes below for<br>additional information.|
{2}------------------------------------------------
|4.0530 – Prevention of Significant<br>Deterioration / 17.0307 - Avoidance<br>Conditions|AEC-1, AEC-2,<br>AEC-4|The previous diesel usage limitation of 250,000<br>gallons per year for AEC-1, AEC-2, and AEC-4 will be<br>retained in order to keep the facility’s potential NOX<br>emissions below the 250 tons per year threshold, and<br>thus, preclude applicability of this regulation.  The<br>facility documents continuous compliance with this<br>limitation through monitoring, recordkeeping, and<br>reporting on a rolling 12-month basis.|
|---|---|---|
|4.1111 – Maximum Achievable Control<br>Technology (40 CFR 63,<br>Subpart ZZZZ)|IC-2|This emergency generator is subject to 40 CFR Part<br>63, Subpart ZZZZ – “National Emission Standards for<br>Hazardous Air Pollutants for Reciprocating Internal<br>Combustion Engines.”  Requirements involve<br>maintenance practices, such as changing the oil and<br>filter, andinspecting thehoses and belts.|
||IC-1, IC-3|These emergency generators are also subject to 40<br>CFR Part 63, Subpart ZZZZ.  For these generators,<br>compliance with NESHAPS Subpart ZZZZ is achieved<br>bycompliance with NSPS Subparts IIII and JJJJ.|
|4.1111 – Maximum Achievable Control<br>Technology (40 CFR 63,<br>Subpart CCCCCC)|ES-120|This gasoline tank is subject to 40 CFR Part 63,<br>Subpart CCCCCC – “National Emission Standards for<br>Hazardous Air Pollutants for Source Category:<br>Gasoline Dispensing Facilities.”  The required<br>management practices include minimizing gasoline<br>spills and cleaning spills expeditiously.|
|4.0515 – Particulates from<br>Miscellaneous Industrial Processes|TO-2|This source is subject to this regulation because it<br>exhausts PM into the outdoor atmosphere.  The PM<br>emission limit for this source is shown in the notes<br>below.|
|4.0516 – Sulfur Dioxide Emissions from<br>Combustion Sources|AEC-1, AEC-2,<br>AEC-4, TO-2,<br>IC-1,<br>IC-2, IC-3|This regulation limits SO2emissions from these<br>sources to 2.3 lb/MMBtu.  The AP-42 SO2emission<br>factor for the diesel test cells and the fire pump is 0.51<br>lb/MMBtu based on 0.5% fuel sulfur content.  The AP-<br>42 SO2emission factor for the gasoline test cell is<br>0.084 lb/MMBtu based on 0.5% fuel sulfur content.<br>The AP-42 SO2emission factor for the natural gas<br>test cells, the thermal oxidizer, and the generators is<br>0.00059 lb/MMBtu.  Thus,the facilityis in compliance.|
|4.0521 – Control of Visible Emissions|Facility-Wide|This regulation limits visible emissions from these<br>sources to no greater than 20% opacity due to their<br>post-1971 manufacture date.  Compliance with this<br>regulation will be determined through facility self-<br>monitoring andAgencyinspections.|
|4.1806 – Control and Prohibition of<br>Odorous Emissions|Facility-Wide|This regulation requires that the facility prevent<br>odorous emissions from causing or contributing to<br>objectionable odors beyond their property line.<br>Compliance with this regulation will be determined<br>through facility self-monitoring and Agency<br>inspections.|



## **REGULATORY NOTES** 

Regarding AB Air Quality Code 4.0515 – Particulates from Miscellaneous Industrial Processes, the allowable emission limit for each emission source was calculated according to the following: 

TO-2: Process Weight = 150 gal/hr x 8.33 lb/gal / 2,000lb/ton = 0.625 ton/hr Allowable Emission Limit = (4.10)*(0.625)[0.67] = 2.99 lb PM/hr Note: Process weight based on density of water.
{3}------------------------------------------------
||||||
|---|---|---|---|---|
||**SECTION D DETAILS**||||
||||||
||**EMISSION INFORMATION**||||
|**Calculation Method Codes**<br>**(List all that apply)**|**1 = Stack test result**<br>**2 = Material (mass) balance**<br>**3 = EPA approved information (AP-42, CTG, etc.)**<br>**4 =Other (specify intable below)**||||
|**Calculation Rejection Codes**<br>**(List all that apply)**|**1 = Calculation error**<br>**2 = Wrong emission factor(s) used**<br>**3 = Control efficiency(ies) not accepted**<br>**4 =Other (specify intable below)**||||
|**Emission Source (ID No.)**|**Calculation**<br>**Method Code**|**Accept or**<br>**Reject?**|**Calculation**<br>**Rejection Code**|**AB Air Quality**<br>**Calculations**<br>**Attached?**|
|Facility-Wide|1, 3|Accept|NA|Yes|



## **EMISSION NOTES** 

AB Air Quality calculated potential emissions with and without operating limits.
{4}------------------------------------------------
## **SECTION E SUPPORTING DOCUMENTATION (Provide brief description of any attachments)** 

1. Title V permit renewal application dated July 5, 2024 

2. Supporting calculations and documentation 

3. Draft Title V permit 

4. Draft permit cover letter 

5. Draft public notice
{5}------------------------------------------------
## **Asheville-Buncombe Air Quality Agency APPLICATION REVIEW SUMMARY** 

|**SECTION A:  FACILITY INFORMATION**|**SECTION A:  FACILITY INFORMATION**|**SECTION A:  FACILITY INFORMATION**|**SECTION A:  FACILITY INFORMATION**|
|---|---|---|---|
|**Company Name:**|RTX Corporation,Pratt and WhitneyDivision|||
|**Site Name:**|Asheville Plant|||
|**Mailing Address:**|330 Pratt and WhitneyBlvd.,Asheville NC 28806|||
|**Site Address:**|330 Pratt and WhitneyBlvd.,Asheville NC 28806|||
|**General Description of Business:**|Airplane Parts Manufacturer|||
|**Facility Classification:**|Small|**Site Status:**|Existing|



|**SECTION B:  APPLICATION INFORMATION**|**SECTION B:  APPLICATION INFORMATION**|**SECTION B:  APPLICATION INFORMATION**|**SECTION B:  APPLICATION INFORMATION**|
|---|---|---|---|
|**Date of Application:**|July 31, 2025|**Application Tracking No.:**|NA|
|**Date Complete Application**<br>**Received:**|August 22, 2025|**Board Meeting Date:**|September 10,<br>2025|
|**Confidentiality Requested?**|NA|**Board Agenda Type:**|Modification|
|**Application Results:**|The purpose of this review is to lend approval to RTX Corporation, Pratt and<br>Whitney Division to modify their permit.|||
|**Permit No. Issued by Application:**|11-920-21C / September 10, 2025|||
|**Permit No. Voided by Application:**|11-920-21B / March 14, 2024|||



## **SECTION C:  REGULATORY INFORMATION** 

**AB Air Quality Regulations:** 4.0515, 4.0516, 4.0521, 4.0524, 4.1104, 4.1111, 4.1806, 17.0704 

## **SECTION D:  FACILITY-WIDE EMISSIONS INFORMATION** 

|**SECTION D:  FACILITY-WIDE EMISSIONS INFORMATION**|**SECTION D:  FACILITY-WIDE EMISSIONS INFORMATION**|**SECTION D:  FACILITY-WIDE EMISSIONS INFORMATION**|**SECTION D:  FACILITY-WIDE EMISSIONS INFORMATION**|
|---|---|---|---|
|**Pollutants Reviewed as a Result**<br>**of this Application or AB Air**<br>**Quality Action:**|**Projected Actual Emissions**<br>**(TONS/YR)**|**Prior Potential**<br>**Emissions**<br>**(TONS/YR)**|**Current Potential**<br>**Emissions**<br>**(TONS/YR)**|
|**CO**|3.9|15.0|15.0|
|**NO**X|3.0|9.8|9.8|
|**PM**|0.8|1.9|2.0|
|**PM10**|0.8|1.9|2.0|
|**PM2.5**|1.1|1.9|2.0|
|**SO2**|0.002|0.01|0.01|
|**VOC**|22.4|45.0|45.0|
|**Greenhouse Gases, CO2e**|2,323.1|5337.9|5741.0|
|**Total HAPs**|0.9|2.3|2.3|
|**List all HAPs>10 TPY**|None.|||
|***Emission numbers denoted with an (*) reflect“controlled” emissions (i.e. emissions reduced by a pollution control device).**||||



|**IN COMPLIANCE WITH EMISSION STANDARDS / RECOMMEND APPROVAL**<br>~~Po~~<br>~~tonGlace~~<br>~~|~~|**IN COMPLIANCE WITH EMISSION STANDARDS / RECOMMEND APPROVAL**<br>~~Po~~<br>~~tonGlace~~<br>~~|~~|**IN COMPLIANCE WITH EMISSION STANDARDS / RECOMMEND APPROVAL**<br>~~Po~~<br>~~tonGlace~~<br>~~|~~|**IN COMPLIANCE WITH EMISSION STANDARDS / RECOMMEND APPROVAL**<br>~~Po~~<br>~~tonGlace~~<br>~~|~~|
|---|---|---|---|
|**Prepared By: **<br>~~Po~~|Allison Glass /<br>~~tonGlace~~<br>~~|~~<br>~~Jame©,Raiford~~|**Date Completed:**<br>~~|Cid~~|08/29/2025<br>~~Cid~~|
|**Reviewed By: **<br>~~Po~~<br>~~FT~~|James C. Raiford /<br>~~ton Glace~~<br>~~|~~<br>~~FT~~<br>~~Jame©,Raiford~~<br>|**Date Reviewed:**<br>~~|~~<br>~~FT~~<br> ~~PP~~|09/03/2025<br><br>~~PP~~|
|**Director:**|AshleyJ. Featherstone /<br>~~Jame ©, Raiford~~<br>——.|**Date Reviewed:**<br>|9/03/2025<br>|