{0}------------------------------------------------
|4.1111 – MACT (40 CFR 63, Subpart<br>ZZZZZZ)|FURNACE1-<br>FURNACE10|This process is subject to 40 CFR Part 63, Subpart<br>ZZZZZZ – National Emission Standards for<br>Hazardous Air Pollutants: Area Source Standards for<br>Aluminum, Copper, and Other Nonferrous Foundries.<br>The process is defined as being a nonferrous foundry<br>that uses material containing chrome, lead, or nickel<br>in amounts greater than or equal to 0.1 percent by<br>weight. The metal ingots used in this process contain<br>chrome and nickel at amounts greater than 0.1%. The<br>rule requires certain management practices including<br>covering or enclosing the melting operation and metal<br>purchasing requirements. There are also<br>recordkeeping andrecordingrequirements.|
|---|---|---|
|4.0515 – Particulates from Miscellaneous<br>Industrial Processes|FURNACE1-<br>FURNACE10<br>, APPS1-<br>APPS5,<br>ALUM1,<br>EBPVD1 –<br>EBPVD5|The allowable emission rate is a function of the<br>process weight rate and shall be determined by the<br>following equation, where P is the process throughput<br>rate in tons per hour (tons/hr) and E is the allowable<br>emission rate in pounds per hour (lbs/hr):<br>E = 4.10 *( P )0.67for P < 30 tons/hr<br>All the processes that have particulate matter<br>emissions were evaluated and emissions were below<br>the allowable emission rate for each process. See the<br>regulatorynotes below.|
|4.0516 – Sulfur Dioxide Emissions from<br>Combustion Sources|SHELL1-<br>SHELL7,<br>WAXFURN1-<br>WAXFURN2,<br>EGEN1 –<br>EGEN5,<br>FWP|This regulation limits SO2emissions from these<br>sources to 2.3 lb/MMBtu.  The AP-42 SO2emission<br>factor for natural gas combustion for small boilers<br>(SHELL1-SHELL7 and WAXFURN1-WAXFURN2) is<br>0.00006 lb/MMBtu.  The AP-42 SO2emission factor<br>for natural gas internal combustion engines<br>(emergency generators EGEN1-EGEN5, FWP) is<br>0.006 lb/MMBtu. Thus, the facility is in compliance.|
|4.0521 – Control of Visible Emissions|FURNACE1-<br>FURNACE10<br>, APPS1-<br>APPS5,<br>ALUM1,<br>EBPVD1 –<br>EBPVD5|This regulation limits visible emissions from each of<br>these sources to no more than 20% opacity due to<br>their post-1971 manufacture date.  Compliance with<br>this regulation will be determined through Agency<br>inspections.|
|4.0605 – General Recordkeeping and<br>Reporting Requirements|Entire facility|The facility is required to submit reports with<br>production data that will facilitate annual emissions<br>calculations bythe agency.|
|4.1806 – Control and Prohibition of<br>Odorous Emissions|Entire Facility|This regulation requires that the facility prevent<br>odorous emissions from causing or contributing to<br>objectionable odors beyond their property line.<br>Compliance with this regulation will be determined<br>through Agencyinspections.|



## **REGULATORY NOTES** 

**4.0515** . The table below shows the calculated allowable emission rates based on the equation E = 4.10 *( P )0.67 for P < 30 tons/hr, where where P is the process throughput rate in tons per hour (tons/hr) and E is the allowable emission rate in pounds per hour (lbs/hr). This is compared to the actual emission rate for each process. 

|Process|Allowable<br>Emission<br>Rate (E)|Actual<br>Emission<br>Rate|Lower<br>than<br>Allowable<br>Rate?|
|---|---|---|---|
|FURNACE1-FURNACE10|2.18E-01|3.00E-06|Yes|
|EBPVD1-EBPVD10|8.83E-02|2.40E-02|Yes|
|APPS1-APPS5|8.36E-02|1.50E-02|Yes|
|ALUM1|9.95E-03|7.50E-02|Yes|
{1}------------------------------------------------
**4.1111** . The facility is subject to 40 CFR Part 63, Subpart ZZZZZZ – National Emission Standards for Hazardous Air Pollutants: Area Source Standards for Aluminum, Copper, and Other Nonferrous Foundries. The process at the facility is defined as “other nonferrous foundry” due to the amount of HAP in the metal it is melting. This rule has is applicable when the annual melt capacity equals or exceeds 600 tons per year. The facility has a maximum process rate of 1,095 tons per year. If the facility were to exceed 6,000 tons per year, additional requirements would apply. 

**17.0700** . The facility submitted air dispersion modeling for chromium with their original permit application because they exceed the TPER for this pollutant. The modeling demonstrated that the facility emissions would be below the AAL for chromium. The facility also exceeded the TPERs for acrolein, benzene, and formaldehyde, but the facility cited the toxics exemption for the emergency engines based on Chapter 17.01029(a)(25) which states “natural gas and propane fired combustions sources with an aggregate allowable heat input less than 450 million Btu per hour that are the only source of benzene at the facility” could be exempted. While this exemption appeared to apply, further investigation into the NCDEQ rule showed that they added “external” to the combustion sources in the rule, thus eliminating internal combustion sources from this rule, and this exemption could no longer apply. 

The emergency engines were still exempt from toxics due to Chapter 17.0702(a)(27)(B), however State Session Law SL-2012-91, which requires the Agency to “review the application to determine if the emission of toxic air pollutants from the source or facility would present an unacceptable risk to human health”. For this application, the toxics review requires air dispersion modeling, and the facility voluntarily submitted modeling for acrolein, benzene, and formaldehyde and included the emergency engines and other natural gas combustion sources. 

With the previous permit modification (11-920-21B), the size of the original engines that were included in the modeling demonstration changed. The total emissions from the new engines are lower than what was previously modeled. Additionally, the engines are now located on the roof which is further from the fence line than the previous engines and will result in better dispersion due to the height of the new stacks. Therefore, no additional modeling is required. The permit was updated with the stack parameters of the new engines. The facility submitted updated parameters on page 8 of their application, and mistakenly used hourly emission rates for benzene when they should have used pounds per year averaged over 8760 hours. The agency used the corrected version in the permit. 

With this permit modification, the permitted aluminide coating process (ALUM1) has changed its recipe resulting in an increase in the potential to emit Hydrogen Fluoride, PM, PM10, and PM2.5. There is raw ingot that is used to generate the coating, and the process will utilize an activator agent. The activator agent has the potential to create Hydrogen Fluoride (HF) from a side reaction. The coating furnaces will vent through a bubbler to remove HF in the exhaust stream, but this control has not been taken into account for calculating potential emissions. The coating furnaces will vent from a horizontal unobstructed stack on top of the building. The emission calculations for this process have been updated to reflect the current raw material use rates. Updated emission calculations are reflected in this permit modification. The potential HF emissions associated with this process are now above the Toxic Pollutant Emission Rates (TPER) due to recipe updates and would require a permit under Chapter 17.0700. The facility conducted an air dispersion modeling analysis using AERSCREEN and was below the Acceptable Ambient Levels (AAL) for both the hourly and 24-hour averaging period as shown in the table below. A permit limitation of 15.9 lbs of activator per 24-hour period for the ALUM1 process will be added to the permit. This is the maximum usage of activator they could use in a 24 hour period, based on having 2 furnaces that use 5.3 pounds of activator per batch, with one batch taking 16 hours to complete. (2 furnaces multiplied by 5.3 pounds per batch divided by 16 hours per batch and multiplied by 24 hours). 

|**Pollutant**|**Averaging**<br>**Period**|**Modeling Result**<br>**(mg/m3) **|**AAL**<br>**(mg/m3) **|**Compliance**<br>**(Y/N)**|
|---|---|---|---|---|
|Hydrogen Fluoride|One-Hour|0.047|0.25|Y|
|Hydrogen Fluoride|24-Hour|0.028|0.03|Y|