{0}------------------------------------------------
## Asheville-Buncombe Air Quality Agency Facility Inspection Report 

**==> picture [446 x 186] intentionally omitted <==**

**----- Start of picture text -----**<br>
Facility Inspection Information<br>Facility Name: | Aprotech Powertrain, LLC<br>Date of Inspection: | March 10, 2025 Last Inspected: | September 21, 2023<br>=.<br>Mailing _ | 31 Adams Hill Road, ; _ | 31 Adams Hill Road,<br> Address: | 1«seville, NC 28806 Physical Location: | 4 «1 aville, NC 28806<br>Contact Name: | Kenneth West & Jim Jones Phone Number: | 828-702-3416<br>|PermitContact Email:#: | 11-867-17|kwest@aprotechgroup.com__|Issued:| July 10, 2017 ere|Expir e s:e| July 30, 2025<br>Inspector(s): | Steve Ensley<br>| Results: | Appears in compliance Inspection Time: | 0900<br>**----- End of picture text -----**<br>


## Safety Equipment / Special Instructions 

Safety glasses and steel-toed shoes are required while in the manufacturing area. 

On March 10, 2025, | traveled to Aprotech Powertrain, LLC and met with Kenneth West to perform an unannounced compliance inspection. Aprotech Powertrain, LLC specializes in manufacturing vibration dampeners for commercial vehicles and agricultural equipment. Mr. West explained that there have been no changes to equipment or production since the last compliance inspection. During the inspection the following sources were observed: 

## Permitted Equipment 

|EMISSION<br>SOURCEID|___EMISSIONSoURCE|EMISSIONSOURCE DESCRIPTION<br>|___EMISSIONSoURCE DEScRIFION |<br>One (1) vibration damper adhesive spray|OBSERVATION<br>OBSERVATION<br>Observed in operation|||
|---|---|---|---|---|
|ES-103|operation controlled byone (1) waterwash||||
||system (CD-103).||||
||One (1) vibration damper primer spray|Observed in operation|||
|ES-104|operation controlled by one (1) waterwash||||
||system (CD-104).||||
||One (1) vibration damper paint spray operation |Observed|Observed in operation|||
|ES-105|controlled by one (1) waterwash system (CD-||||
||105)||||
|||4were in the main line|using||
|ES-106|Five (5) vibration damperdip tanks.|tolueneas lubricant.<br>1<br>4<br>as tuprican’.<br>was <br>a separate area and used||i<br> in|
|||Murphy’sOilSoapinstead.|||



: 

1 |
{1}------------------------------------------------
Aprotech Powertrain, LLC Facility Inspection Report March 10, 2025 

## Exempt Sources: 

## Permit Conditions: 

## The following permit conditions were reviewed during this inspection: 

- e A.14-This condition requires the facility retain a copy of the permit on the premises. The facility had a copy of their current operating permit on-site. 

- e B.2—This condition states the facility shall be operated to prevent odorous emissions from being emitted beyond the boundary of the facility. No odors were observed 

   - beyond the boundary of the facility. 

- e 8B.3-This condition establishes the facility's particulate matter emission limit from ES103, ES-104, and ES-105. This regulation limits PM emissions from ES-103, ES-104, and ES-105 to 16.51 pounds per hour each. Per updated emission calculations made by AB Air Quality, ES-103, ES-104, and ES-105 emit 0.009, 0.006, and 0.007 pounds of PM per hour, respectively. Provided the facility maintains the overspray collection systems on the paint spray booths, it will be assumed these operations are in compliance with this regulation. The facility is aware of the particulate matter emission limit and is using waterwash systems on ES-103, ES-104, and ES-105 to control and minimize emissions from the associated spray operations. 

- e B.4-This condition limits visible emissions from all sources to no more than 20 percent opacity when averaged over a six-minute period. Emission release points were observed with no visible emissions during the inspection. 

2|Pag
{2}------------------------------------------------
Aprotech Powertrain, LLC Facility Inspection Report March 10, 2025 

- e B.5—The facility has triggered an air toxics review under AB Air Quality Code 17.0700 and 4.1100. In order to comply with the requirements of this condition, the facility is required to monitor and maintain records of annual emissions of trichloroethylene calculated monthly. According to Kenneth West, they have not used trichloroethylene in years and removed all processes that utilize tricholorethylene. 

- e B.6-This condition requires that the facility submit annual emission reports for VOCs and HAPs. The facility is submitting annual reports as required. The most recent annual report was received on February 7, 2025 and contained all the required information. 

## Compliance History: 

The facility does not have any history of recorded violations in the last ten (10) years. 

## Conclusion: 

Based on the above information, Aprotech Powertrain, LLC appears to be in compliance with all applicable regulations of the AB Air Quality Code. It is recommended that this permit be renewed. 

**==> picture [439 x 103] intentionally omitted <==**

**----- Start of picture text -----**<br>
Signature: x | U—— - : x Date: Sf 18 [as<br>Reviewer Signature: # Wy js, Om Date: 3) {| 125<br>Director Signature: | A | y Date: 9 IG | 9OL5<br>**----- End of picture text -----**<br>
{3}------------------------------------------------