{0}------------------------------------------------
#### Asheville-Buncombe Air Quality Agency APPLICATION REVIEW SUMMARY 

##### **SECTION A: FACILITY INFORMATION** 

|Company Name:|Taylor Frizsell dba Bee Tree Disposal|
|---|---|
|Site Name:|Bee Tree Disposal|
|MailingAddress:|850 Warren Wilson Road, Swannanoa,NC28778|
|Site Address:|850 Warren Wilson Road, Swannanoa,NC28778|
|General DescriptionofBusiness:|Organic Waste Incinerator<br> <br>|
|Facility Classification:|Title V<br>ISite Status:<br>INew|



##### **SECTION B: APPLICATION INFORMATION** 

|DateOfApplication:|April 23, 2026|ApplicationTracking No.:|N/A|
|---|---|---|---|
|Date CompleteApplication<br>Received:|April23,2026|Board Meeting Date:|May 14, 2026|
|ConfidentialityRequested?|No|BoardAgendaType:|New|
|ApplicationResults:|The purpose of this<br>incinerator subjectt|reviewistoissue a general TV p<br>oNSPS CCCC.|ermit foranair curtain|
|PermitNo./Date Issuedby<br>Application:|11-929-26 / May 14|, 2026||
|PermitNo./Date Voidedby<br>Application:|N/A|||



##### **SECTION C: REGULA TORY INFORMATION** 

AB Air Quality Regulations: j 4.0524, 4.1904, 17.0500, 17.0509, 17.0510 

##### **SECTION D: FACILITY-WIDE EMISSIONS INFORMATION** 

|Pollutants Reviewed as a Result<br>ofthisApplicationorABAir<br>QualityAction:|ActualEmissions(TONS/YR)<sup>1</sup>|PotentialEmissions(TONS/YR)<sup>1</sup>|
|---|---|---|
|**PM-Total**<br>-|--|25.70|
|**PM-10/PM-2.5**|--|10.19|
|SO2|--|1.91|
|NOx|--|20.40|
|co|--|47.91|
|voe|--|20.25|
|Greenhouse Gases (GHG),CO2e|--|60,595.37|
|All HazardousAirPollutants<br>**(HAPs)**|--|0.002|
|Listall**HAPs>1OTPY**of<br>|None||



###### potential emissions 

*Emission numbers denoted with an(*) reflect "controlled" em issions (i.e. emissions reduced by a pollution control device).<sup>1</sup> Potential emissions reported to be <100 are caooed at those levels with federally enforceable permit limits. 

##### **IN COMPLIANCE WITH SION STANDARDS/ RECOMMEND APPROVAL** 

|PreparedBy:|James C. Raiford/|Date Completed:|05/07/2026|
|---|---|---|---|
|ReviewedBy:|Ashley J. Featherston .|Date Reviewed:|05/07/2026|
|Director:||DateApproved:|05/07/2026|
{1}------------------------------------------------
#### **SECTION A DETAILS** 

##### **FACILITY INFORMATION [Detailed discussion of any items in Section A]** 

Taylor Frizsell dba Bee Tree Disposal has applied for a general Title V permit to operate a trench-style air curtain incinerator at the address listed above. The air curtain incinerator will handle only wood waste/clean lumber/yard waste from storm debris clean up and from customers bringing brush and material to the site. No municipal solid waste, treated/painted wood, or prohibited materials are to be accepted. 

The agency submitted a draft general permit for air curtain incinerators to EPA for review and also issued a public notice for the general permit on August 1, 2019. General permits for owners and operators can be issued without going back to notice and EPA review, as described below. NC DAQ has modified their state burning regulations after our initial public notice was issued. Permit condition 2.1A.2.(f) contains a requirement that has been removed from the state rule. The agency is in the process of updating our rules and will issue a revised general permit to public notice to reflect the update. 

###### **Information for the General Title V Permit:** 

An air curtain incinerator (ACI) means a stationary or portable incinerator that operates by forcefully projecting a curtain of air across an open, integrated combustion chamber (fire box) or open pit or trench (trench burner) in which combustion occurs. Incinerators of this type can be constructed above or below ground and with or without refractory walls and floor. Air curtain incinerators are different from conventional combustion devices which typically have enclosed fireboxes and controlled air technology such as mass burn, modular, and fluidized bed combustors. 

Section 129 of the Clean Air Act directs the Environmental Protection Agency's (EPA) Administrator to develop regulations under Section 111 of the Act limiting emissions of nine air pollutants (i.e., particulate matter, carbon monoxide, dioxins/furans, sulfur dioxide, nitrogen oxides, hydrogen chloride, lead, mercury, and cadmium) from four categories of solid waste incineration units: municipal solid waste; hospital, medical and infectious solid waste; commercial and industrial solid waste; and other solid waste. EPA promulgated the New Source Performance Standards (NSPS) and Emission Guidelines (EG) to reduce air pollution from commercial and industrial solid waste incineration (CISWI) units, under Subparts CCCC and DODD. Those standards and guidelines apply to incinerators, also known as CISWI units, used by commercial and industrial facilities to burn non-hazardous solid waste. NSPS Subpart CCCC applies to new CISWI units that commenced construction after June 4, 2010, or that commenced reconstruction or modification after August 7, 2013 while NSPS Subpart DODD applies to existing CISWI units. 

An air curtain incinerator is a CISWI unit that shall meet certain provisions of NSPS Subpart CCCC if the following conditions are met. Pursuant to 40 CFR 60.2020, air curtain incinerators that burn only the materials listed in paragraphs (1) through (3) below are only required to meet the requirements under "Air Curtain Incinerators" (40 CFR 60.2245 through 60.2260) 

- (1) 100 percent wood waste: _Wood waste means untreated wood and untreated wood products, including tree stumps (whole or chipped), trees, tree limbs (whole or chipped), bark, sawdust, chips, scraps, slabs, mi/lings, and shavings. Wood waste does not include: Grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs from residential, commercial/retail, institutional, or industrial sources as part of maintaining yards or other private or public lands, construction, renovation, or demolition wastes, or clean lumber._ 

- (2) 100 percent clean lumber: _Clean lumber means wood or wood products that have been cut or shaped and include wet, air-dried, and kiln-dried wood products. Clean lumber does not include wood products that have been painted, pigment-stained, or pressure-treated by compounds such as chromate copper arsenate, pentachlorophenol, and creosote._ 

- (3) 100 percent mixture of only wood waste, clean lumber, and/or yard waste. _Yard waste means grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs. They come from residential, commercial/retail, institutional, or industrial sources as part of maintaining yards or other private or public lands._
{2}------------------------------------------------
Also, the owner or operator of each CISWI and air curtain incinerator (ACI) shall apply for and obtain a Title V operating permit pursuant to 40 CFR 60.2242 as required by Section 129(e) and Title V of the Clean Air Act. 

Therefore, air curtain incinerators shall be subject to AB Air Quality Code 17.0500, Title V Procedures. The owner or operator of a new ACI as defined above and in 40 CFR 60.2015 that meets the requirements in 40 CFR 60 .2020(i) shall obtain a General Title V Operating Permit pursuant to AB Air Quality Code 17.0509 Permitting of Numerous Similar Facilities. Pursuant to AB Air Quality Code 17.0509, the Director may issue, after notice and opportunity for public participation· provided in AB Air Quality Code 17.0521, a permit to cover numerous similar facilities or sources. 

The purpose of this engineering review is to evaluate the rules and standards applicable to the commercial air curtain incinerators that burn 100 percent wood waste, 100 percent clean lumber, and 100 percent mixture of only wood waste, clean lumber and/or yard waste.
{3}------------------------------------------------
#### **SECTION B DETAILS** 

|**[Listalle**<br>**associate**|**APPLICATIO**<br>**mission sources (permittedandexe**<br>**d control devices and pollutants. P**<br>**Section B at bottom u**<br>|**N INFORMATIO**<br>**mpt) reviewedas**<br>**rovide a detailed d**<br>**nder "Application**|**N**<br>**a result of this application, their**<br>**iscussion of any other itemsin**<br>**Notes"]**|
|---|---|---|---|
|**Emission**<br>**SourceID**|**Emission Source Description**<br>**1.**<br>**Type, manufacturer, capacity**<br>**2.**<br>**Control device withID(if any)**|**Pollutant(s)**<br>**Emitted**|**Miscellaneous Notes**|
|AC1|Air Curtain Destructor CP 2000T or<br>McPherson M30 Air Destructor|PM,PM-10, PM-<br>2.5, CO, SO2,<br>NOx,voe,<br>CO2e|Maximum charge rate of 10 tons<br>per hour. Powered by a small<br>diesel fired engine. The site will<br>first operate with theCP2000T,<br>which was listed on the first<br>applicationashaving a maximum<br>charge rate of10tons per hour.<br>They may switch to using the<br>M30, which has the same<br>maximum rating. Since this is a<br>trench style air curtain there<br>shouldbeno discernable<br>difference between running either<br>piece of equipment at the site.|



##### **APPLICATION NOTES** 

The original application was received on April 2, 2026 and the current application is dated April 23, 2026. The facility emailed Buncombe County Planning Department on April 21, 2025 asking for a zoning consistency determination. The Agency has not received a zoning consistency determination from Buncombe County planning, but fifteen days have elapsed since the email and therefore fulfills the requirement that the zoning authority is notified. Specific Condition 2.E states that the permittee is required to comply with all lawfully adopted local ordinances, and that the local zoning authority is responsible for enforcing those ordinances. 

The facility is in the process of registering the name "Bee Tree Disposal". In order to have a responsible party, the permit will be listed with the applicant's name and "doing business as (OBA)" the proposed business name. The facility will apply for an administrative amendment when they have finalized their business registration with the State of North Carolina. 

The site location was reviewed as part of the modeling demonstration, and the location of the trench burner is not within 300 feet of any occupied dwellings on adjoining property.
{4}------------------------------------------------
#### **SECTION C DETAILS** 

##### **REGULATORY INFORMATION** 

**(Identify the AB Air Quality Regulations reviewed because of this application. At a minimum, the regulations already listed should be reviewed and reason given for applicability or nonapplicability. If a regulation has a standard, list the standard and indicate how the source is in** 

||**compliance. **<sup>**1**</sup><br>**Emission**||
|---|---|---|
|**AB Air Quality RegulationNumber/Title**|**SoNuor(cse)_ID**<br>**Subject**|**NotesonRegulation**<br>(Compliance demonstration, applicability, etc.)|
|17.0500 - Title V Procedures|AC1|Title V does applytothis facility at this time.<br>Calculated potential emissions for this<br>facility are below Title V permitting<br>thresholds, however, Section 129( e) and<br>Title V of the Clean Air Act require the<br>owneroroperator of each CISWI and air<br>curtain incinerator (ACI}toapply forand<br>obtain a Title V operatingpermit pursuantto<br>40CFR 60.2974.|
|||NSPS does applytothis facility. This facility<br>issubject to40CFR Part60Subpart CCCC<br>"Standards of Performance for Other Solid<br>Waste Incineration Units for Which<br>ConstructionisCommenced After June4,<br>2010,orfor Which Modification or<br>|
|4.0524 - New Source Performance<br>Standards|AC1|ReconstructionisCommencedonor After<br>August 7, 2013".Visible emissions are<br>limitedto10 percent opacity (6-minute<br>average), except35percent opacity (6-<br>minute average) during the startup period<br>thatiswithin the first30minutes of<br>operation.<br>EPA Method 9 testing for opacityisrequired<br>initiallyandannually.|
|4.1904 - Air Curtain Burners|AC1|Air quality permits are required for air<br>curtain burners subject to40CFR Part 60<br>Subpart CCCC 60.2245 through 60.2260.<br>WNCRAQA Code 4.1904 has several work<br>practice standards that apply, including a<br>setback requirement of 300 feet from the<br>nearest occupied dwelling not locatedon<br>the property where the burningis<br>conducted.|
|4.1806 - ControlandProhibitionof<br>Odorous Emissions|AC1|The facility must not cause or contribute to<br>objectionable odors beyond the facility's<br>boundary.|



##### **REGULATORY NOTES** 

###### **17.0509 Permitting of Numerous Similar Facilities** 

Air curtain incinerators are very similar facilities with regard to operation and resulting emissions, and therefore may be granted a General Title V Permit by the Director in accordance with AB Air Quality Code 17.0509 below. 

**17.0509 Permitting of Numerous Similar Facilities** 

- (a) The Director may issue, after notice and opportunity for public participation provided in Rule .0521 of this Section (Title V Procedures}, a permit to cover numerous similar facilities or sources. 

- (b) The Director shall not issue a permit under this Rule unless the following conditions are met:
{5}------------------------------------------------
- (1) There is no unique difference that would require special permit conditions for any individual facility; and (2) No unique analysis is required for any facility covered under the permit. 

- (c) A permit issued under this Rule shall comply with all the requirements of this Section. 

- (d} A permit issued under this Rule shall identify criteria by which facilities or sources may qualify for the permit. To facilities or sources that qualify, the Director shall grant the terms and conditions of the permit. 

- ( e) The facility or source shall be subject to enforcement action for operating without a permit if the facility or source is later determined not to qualify for the terms and conditions of the permit issued under this Rule. 

- (f) Sources subject to Title IV shall not be eligible for a permit issued under this Rule. 

- (g) The owner or operator of a facility or source that qualifies for a permit issued under this Rule shall apply for coverage under the terms of the permit issued under this Rule or shall apply for a regular permit under this Section. 

- (h} The Agency need not repeat the public participation procedures required under Rule .0521 of this Section (Title V Procedures) when it grants a request by a permit applicant to operate under a permit issued under this Rule. 

###### **17.0510 Permitting of Facilities at Multiple Temporary Sites** 

Since air curtain burners are often built as temporary mobile operations, AB Air Quality Rule 17.0510 states that the Director can issue a single permit for operation at multiple temporary sites under the following conditions. 

###### **17.0510 Permitting of Facilities at Multiple Temporary Sites** 

- (a) The Director may issue a single permit authorizing emissions from similar operations by the same facility owner or operator at multiple temporary sites. 

- (b) In order for a facility to qualify for a permit for multiple temporary site under this Rule, the operation must involve at least one change of site during the term of the permit. 

- (c) Sources subject to Title IV shall not be eligible for a permit under this Section. 

- (d) Permits for facilities at multiple temporary sites shall include: 

- (1) identification of each site; 

- (2) conditions that will assure compliance with all applicable requirements at all authorized locations; 

- (3) requirements that the permittee notify the Agency at least 10 days in advance of each change of location; and 

- (4) conditions that assure compliance with all other provisions of this Section. 

A condition will be included in the permit to require that the permittee notify the agency at least 10 days in advance of each change of location and obtain a zoning consistency letter for each location. North Carolina General Statute§ 143-215.108(f) requires that applications for air quality permits for new or expanded facilities include a request for a zoning consistency determination. 

###### **4.1904 Air Curtain Burners** 

Chapter 4.1904(b )(5) requires dispersion modeling analysis to be performed to protect the ambient air quality standard and prevention of significant deterioration (PSD) increment for particulate. This modeling analysis was performed by James Raiford of this Agency and documented via memorandum on May 7, 2026. This modeling shows compliance with the total solid particulate state standard, and the PM10 and PM2.5 National Ambient Air Quality Standards. This facility is limited to operating for only 10 hours a day per Chapter 4.1904(c)(4), and emissions were modeled with that restriction. See the table below. The modeling demonstration is documented here and not included in the general permit. 

|**Pollutant**|**Averaging**<br>**Period**|**Background**<br>**Concentration**<br>(µg/m3)|**Modeled**<br>**Impact**<br>(µg/m3)|**Total**<br>(µg/m3)|**AAQS**<br>**(µg/m3)**|**%AAQS**|
|---|---|---|---|---|---|---|
|PM25|24-hour|16|9.78|25.78|35|74%|
|.|Annual|6.1|1.17|7.27|9|81%|
|PM10|24-hour|12.4|13.96|26.36|150|18%|
|TSP|24-hour|--|24.76|24.76|150|17%|
||Annual|--|1.49|1.49|75|2%|
{6}------------------------------------------------
|**Calculation Method Codes**<br>(List all that apply)|**SECTION**<br>**EMISSION I**<br>1=**Stack test result**<br>**2**=**Material (mass)**b<br>**3**=**EPA**approvedinf<br>**4**=**Other (specifv**in|**D DETAIL**<br>**NFORMATIO**<br>alance<br>ormation**(AP-42,**<br>table**below)**|**S**<br>**N**<br>**CTG, etc.)**||
|---|---|---|---|---|
|**Calculation Rejection Codes**<br>(List all that apply)|**1**=Calculationerror<br>**2**=**Wrong emission f**<br>**3**=Control efficiency<br>**4**=Other**(specifv**in|<br>**actor(s)**used<br>(ies)**not**accepte<br>table**below)**|d||
|**Emission Source (ID No.)**|**Calculation**<br>**Method Code**|**Accept**or<br>**Reject?**|**Calculation**<br>**Rejection Code**|**AB Air Quality**<br>**Calculations**<br>**Attached?**|
|AC1|3,4|NA|NA|Yes|



##### **EMISSION NOTES** 

Emissions calculations come from two sources: San Joaquin Valley APCD, and USDA Forest Service. SJV APCD was used for PM, SOx, NOX, CO and VOC, while Greenhouse Gas emissions were obtained from USDA Forest Service. Emissions were also calculated for the engine using AP-42. 

Total emissions included those from the internal combustion engine.
{7}------------------------------------------------
#### **SECTION E** 

**SUPPORTING DOCUMENTATION (Provide brief description of any attachments)** 

1. Draft of permit 

2. Emissions estimates prepared by agency staff 3. Permit application and copy of check for fee 4. Zoning consistency email 5. Modeling Memo