{0}------------------------------------------------
## **SECTION C DETAILS** 

|**SECTION C DETAILS**|**SECTION C DETAILS**|**SECTION C DETAILS**|
|---|---|---|
|**REGULATORY INFORMATION**<br>**(Identify the AB Air Quality Regulations reviewed because of this application.  At a minimum, the**<br>**regulations already listed should be reviewed and reason given for applicability or non-**<br>**applicability.  If a regulation has a standard, list the standard and indicate how the source is in**<br>**compliance.)**|||
|**AB Air Quality Regulation Number / Title**|**Emission**<br>**Source ID**<br>**No(s).**<br>**Subject**|**Notes on Regulation**<br>(Compliance demonstration, applicability, etc.)|
|17.0500 – Title V Procedures|NA|Title V does apply to this facility at this time.<br>Calculated potential emissions for this<br>facility are below Title V permitting<br>thresholds, however, Section 129(e) and<br>Title V of the Clean Air Act require the<br>owner or operator of each CISWI and air<br>curtain incinerator (ACI) to apply for and<br>obtain a Title V operating permit pursuant to<br>40 CFR60.2974.|
|4.0524 – New Source Performance<br>Standards|AC1|NSPS does apply to this facility.  This facility<br>is subject to 40 CFR Part 60 Subpart CCCC<br>“Standards of Performance for Other Solid<br>Waste Incineration Units for Which<br>Construction is Commenced After June 4,<br>2010, or for Which Modification or<br>Reconstruction is Commenced on or After<br>August 7, 2013”. Visible emissions are<br>limited to 10 percent opacity (6-minute<br>average), except 35 percent opacity (6-<br>minute average) during the startup period<br>that is within the first 30 minutes of<br>operation.<br>EPA Method 9 testing for opacity is required<br>initially and annually.|
|4.1904 – Air Curtain Burners|AC1|Air quality permits are required for air<br>curtain burners subject to 40 CFR Part 60<br>Subpart CCCC 60.2245 through 60.2260.<br>WNCRAQA Code 4.1904 has several work<br>practice standards that apply, including a<br>setback requirement of 300 feet from the<br>nearest occupied dwelling not located on<br>the property where the burning is<br>conducted.|
|4.1806 – Control and Prohibition of<br>Odorous Emissions|AC1|The facility must not cause or contribute to<br>objectionable odors beyond the facility’s<br>boundary.|



## **REGULATORY NOTES** 

## **17.0509 Permitting of Numerous Similar Facilities** 

Air curtain incinerators are very similar facilities with regard to operation and resulting emissions, and therefore may be granted a General Title V Permit by the Director in accordance with AB Air Quality Code 17.0509 below. 

## **17.0509 Permitting of Numerous Similar Facilities** 

- (a) The Director may issue, after notice and opportunity for public participation provided in Rule .0521 of this Section (Title V Procedures), a permit to cover numerous similar facilities or sources. 

- (b) The Director shall not issue a permit under this Rule unless the following conditions are met:
{1}------------------------------------------------
- (1) There is no unique difference that would require special permit conditions for any individual facility; and (2) No unique analysis is required for any facility covered under the permit. 

- (c) A permit issued under this Rule shall comply with all the requirements of this Section. 

- (d) A permit issued under this Rule shall identify criteria by which facilities or sources may qualify for the permit. To facilities or sources that qualify, the Director shall grant the terms and conditions of the permit. 

- (e) The facility or source shall be subject to enforcement action for operating without a permit if the facility or source is later determined not to qualify for the terms and conditions of the permit issued under this Rule. 

- (f) Sources subject to Title IV shall not be eligible for a permit issued under this Rule. 

- (g) The owner or operator of a facility or source that qualifies for a permit issued under this Rule shall apply for coverage under the terms of the permit issued under this Rule or shall apply for a regular permit under this Section. 

- (h) The Agency need not repeat the public participation procedures required under Rule .0521 of this Section (Title V Procedures) when it grants a request by a permit applicant to operate under a permit issued under this Rule. 

## **17.0510 Permitting of Facilities at Multiple Temporary Sites** 

Since air curtain burners are often built as temporary mobile operations, AB Air Quality Rule 17.0510 states that the Director can issue a single permit for operation at multiple temporary sites under the following conditions. 

## **17.0510 Permitting of Facilities at Multiple Temporary Sites** 

- (a)  The Director may issue a single permit authorizing emissions from similar operations by the same facility owner or operator at multiple temporary sites. 

- (b) In order for a facility to qualify for a permit for multiple temporary site under this Rule, the operation must involve at least one change of site during the term of the permit. 

- (c) Sources subject to Title IV shall not be eligible for a permit under this Section. 

- (d) Permits for facilities at multiple temporary sites shall include: 

- (1) identification of each site; 

- (2) conditions that will assure compliance with all applicable requirements at all authorized locations; 

- (3) requirements that the permittee notify the Agency at least 10 days in advance of each change of location; and 

- (4) conditions that assure compliance with all other provisions of this Section. 

A condition will be included in the permit to require that the permittee notify the agency at least 10 days in advance of each change of location and obtain a zoning consistency letter for each location. North Carolina General Statute § 143-215.108(f) requires that applications for air quality permits for new or expanded facilities include a request for a zoning consistency determination. 

## **4.1904 Air Curtain Burners** 

Chapter 4.1904(b)(5) requires dispersion modeling analysis to be performed to protect the ambient air quality standard and prevention of significant deterioration (PSD) increment for particulate. This modeling analysis was performed by James Raiford of this Agency via memorandum on November 11, 2025. This modeling shows compliance with the total solid particulate state standard, and the PM10 and PM2.5 National Ambient Air Quality Standards. While the PM2.5 modeling number was close to the 24 hour national standard, it was conservatively modeled assuming 24 hours of operation. This facility is limited to operating for only 10 hours a day per Chapter 4.1904(c)(4), so compliance with the standards is expected. See the table below. The modeling demonstration is documented here and not included in the general permit. 

|**Pollutant**|**Averaging**<br>**Period**|**Background**<br>**Concentration**<br>**(µg/m3)**|**Modeled**<br>**Impact**<br>**(µg/m3)**|**Total**<br>**(µg/m3) **|**AAQS**<br>**(µg/m3) **|**% AAQS**|
|---|---|---|---|---|---|---|
|PM2.5|24-hour|16|17.95|33.95|35|97.00%|
||Annual|6.1|1.75|7.85|9|87.22%|
|PM10|24-hour|12.4|25.22|37.62|150|25.10%|
|TSP|24-hour|--|98.24|98.24|150|65.49%|
||Annual|--|2.22|2.22|75|2.96%|