{0}------------------------------------------------
Buncombe County Planning and Development Long Range Planning Division 46 Valley St. Asheville, NC 28801 

## **LIGHTING MEMORANDUM** 

**To: Buncombe County Planning Board From: Long Range Planning Division Date:    September 2, 2025 (UPDATED October 6, 2025) Re: Text Amendments Addressing Exterior Lighting Standards** 

## **PURPOSE** 

The Exterior Lighting Memorandum provides an overview of the key issues and proposed Zoning Ordinance changes related to outdoor lighting. Lighting standards are intended to minimize light pollution, light trespass and glare, and work to promote energy efficient lighting practices. Reducing light pollution has important benefits for the natural environment, such as protecting migrating and nesting wildlife, and has been shown to positively impact human health. 

This document will summarize an analysis of Equity issues, relevant case law, current bills before the General Assembly, a consideration of regulations in other jurisdictions, proposed text amendments, and general recommendations. 

## **IMPACT ANALYSIS** 

When exterior lighting pervades the night sky and landscape in ways that negatively impact humans and the environment it is called light pollution. Exposure to light pollution has been found to have negative mental and physical impacts to humans, such as by disrupting the body’s circadian rhythm that regulates sleep, and increasing traffic accidents due to glare and night blindness (3). It also creates impacts that can harm wildlife, plants, and ecosystems that we rely on for a healthy and resilient environment (1). 

A study of outdoor lighting in the United States showed that non-white communities and renter-occupied areas were impacted by light pollution at a rate twice that of white communities, and that there was little difference in the inequity when studying rural vs. urban areas. Some of this can be attributed to development patterns that result in racial and ethnic minorities, and low-income households being situated near less desirable uses that are more likely to create light pollution (2). “Marginalized communities generally suffer from poor lighting, which is visually distressing, environmentally harmful and socially hostile” (4). As a result, light pollution is an environmental justice issue as it disproportionately impacts communities of color and lower socioeconomic households. 

As Buncombe County continues to grow, conflicts between residents and businesses will increase as more areas become developed and new exterior lighting is installed. Infill development, up-zoning, and redevelopment will contribute to a brighter nighttime environment unless protections are put in place to limit the negative impacts of light pollution.
{1}------------------------------------------------
## **CASE LAW & CURRENT BILLS** 

In North Carolina, local jurisdictions have the authority under Zoning law to regulate land uses and standards related to them, such as for exterior lighting. The NC General Assembly prohibits blinding, deceptive or distracting lights which could result in a motor vehicle accident or be confused for a traffic signal (G.S. 13632.2). Two Supreme Court cases related to the regulation of on vs. off-premise sign regulations include: Reed v. Town of Gilbert, and Austin v. Reagan National. 

## _**Current Bills in NC General Assembly**_ 

None identified. 

## **REGULATIONS IN OTHER JURISDICTIONS** 

This is a brief look at what other local governments are doing. _Examples from outside North Carolina may not be legal or otherwise desirable in North Carolina but are presented to illustrate alternative approaches._ 

## _**Common Language and Practices**_ 

Examples of standards from other jurisdictions include: 

|Light level|Regulates the maximum amount of light at property lines, roads, and for the entire<br>development site or withinparkinglots,often through footcandle measurements.|
|---|---|
|Color Temperature|Regulates the color of light on the kelvin scale. 1,000 to 4,500 kelvin is warm light<br>4,500 to 6,500 is white daylight. 6,500 to 10,000 is blue light. Typically warmer<br>colors are healthier and easier on human eyes,and less disruptive to wildlife.|
|Mounted height|Sets a maximum height for the mounting of lights or illuminated signage. Height is<br>one factor that impacts how much light is visible to surrounding properties, and<br>how much of an area is illuminated.|
|Internal illumination|Sets standards for the maximum face size of internallyilluminated signs.|
|Light direction|Light direction dictates where the light falls based on fixture design and placement.<br>Standards to minimize light trespass may include shielding, glare control, or cutoff<br>light fixtures.|
|Lumens|Sets standards for the maximum amount of visible light through limits on lumens.<br>Lumens is the brightness of the light.|
|Movement|Regulates orprohibits animation,movement,or change on a digital displaysign.|
|Automation|Lights can be automated to automatically dim after a certain time of night, turn off<br>during daylight, or adjust brightness during fog and rain. Typically utilized for traffic<br>safetyreasons.|



## _**Common Regulatory Obstacles**_ 

Enforcement of exterior lighting regulations can be difficult when applied to single-family residential developments. For example, when residents add new light fixtures or change old light fixtures they are not required to obtain a Zoning permit, so there is no process for a Zoning inspector to ensure that the light is compliant. Coordination with the Permits & Inspections Department through their electrical permitting process would be needed to enforce exterior lighting standards for single-family residential uses. Therefore, no standards are being proposed for detached single-family uses in these text amendments.
{2}------------------------------------------------
## _**Health & Safety Requirements:**_ 

Regulating a specific use through the Zoning Ordinance does not exempt that use from any other local, state, or federal regulation. As an example, lighting standards are subject to the following requirements: 

- NC State Building Code Requirements for health, safety, and emergency access lighting 

- NCDOT Street light requirements for public roads 

- FAA requirements for Airport lighting related to the airfield side of the property 

## _**Regulation and Enforcement**_ 

Regulation of lighting is through the normal permitting process of obtaining a Site Plan Review (SPR) permit for construction of a building, installation or replacement of lighting, or through a Change of Use permit if a residential structure were converted to commercial use. As is common with most of our regulations, Zoning enforcement for a violation of the lighting requirements would be initiated by receipt of a community complaint for non-compliant lighting. 

## _**Localities**_ 

The following is a list of notable lighting standards from other jurisdictions: 

|**LOCATION**|**REGULATORY EXAMPLES**|
|---|---|
|Asheville, NC|Regulates residential and commercial lighting, requiring full cutoff fixtures. Limits light at<br>property lines to 0.5 footcandles, mounted height to 25 feet, and flood lights less than<br>1,250 lumens and shielded. Requires BUG rating and 4,300 kelvin or less. 6,500 lumens or<br>less in residential districts and 20,000 lumens or less for non-residential. Additional<br>requirements for other uses. Prohibits blinking or changing displays and internally lit wall<br>panels. Exempts temporary seasonal lighting, historic landmark lighting, string lights for<br>residential or over diningareas,and ornamentalgas lights.|
|Henderson<br>County, NC|Requires exterior lighting be fully shielded with exceptions for flag poles and other uses.<br>Sets a maximum amount of light trespass at property lines, and prohibits flood lights.<br>Requires existing buildings to bring lighting into full compliance if they repair or replace<br>50% or more total existingexterior lightingwithin a 12 monthperiod.|
|Chatham<br>County, NC|Requires lighting in natural areas to be reduced after midnight. Requires lighting plans to<br>demonstrate how they will be energy efficient, reduce lighting, and utilize timers or other<br>methods to eliminate lights. Sets standards specific to type of use. Sets standards for light<br>measurement techniques forpermitting.|
|Guilford<br>County, NC|Requires commercial lighting adjacent to a residence be turned off by 10pm. All lights<br>must be full cutoff, mounted less than 35 feet, with footcandle limits based on type of use.<br>Specific standards for canopy lighting and outdoor recreation. Exempts single family<br>residential lighting, temporary lighting and holiday displays, security lighting with motion<br>activation that turns off after 15 minutes, gas lamps, street lights, and government flags.<br>Prohibits flashingor intermittent lighting.|
|Wendell, NC|Specifies a maximum light level of 0.5 footcandles at residential property lines, and up to 1<br>foot candle at all other property lines. Limits wall packs to building entrances only,<br>prohibiting them for general site lighting. Prohibits any light which shines directly into the<br>yard or window of an adjacent residence. Sets a maximum mounted height of 18 feet for<br>pedestrian lights and 37 feet for street orparkinglot lighting.|



## **EXISTING COUNTY ORDINANCES**
{3}------------------------------------------------
Buncombe County’s Zoning Ordinance currently regulates exterior lighting related to commercial uses, multifamily apartment complexes, and dusk-to-dawn security lighting. Standards require full cutoff lighting, or partial cutoff fixtures for lights less than 1,250 lumens. There are limits on the maximum average light level for the overall development, as well as for light levels at property lines, road rights-of-way, and in parking lots. 

Specific standards apply based on type of use, for example, wall accent lighting, gas station canopy lights, streetlights, and sports fields have additional requirements. LED lights are limited to a maximum color temperature of 4,300 kelvin, which is in the warmer yellow range. There is a 35 foot height limit, and glare control requirements. Exemptions exist for temporary seasonal lighting, emergency lighting, and single-family residential lighting (except not dusk-to-dawn lights). Search lights, laser lights, high intensity string lights, and up-lighting are all prohibited. 

## **PROPOSED TEXT AMENDMENTS** 

The following table summarizes the proposed Zoning Ordinance Text Amendments related to co-living. 

||**SUMMARY OF PROPOSED TEXT AMENDMENTS**<br>_(Sec. 78-668 Lighting Standards)_|
|---|---|
|1|Create a definition of accent lighting|
|2|Create a definition of electronic message display|
|3|Create a definition for facade lighting|
|4|Update the lighting standard Purpose statement.|
|5|Remove the assemblyreplacement standard(b)(2)as this is redundant.|
|6|Remove dusk to dawn 5-year conformity standard as these lights were already phased out years ago|
|7|EXEMPTIONS:<br>a) Add exemption for low-intensity ornamental gas flame lamps<br>b) Add exemption for low volt,low watt ornamental landscape lighting|
|8|PROHIBITIONS:<br>a) Clarify prohibition for outward lighting and any that is not full or partial cutoff<br>b) Clarify standards for lumen ratings of string lights<br>c) Prohibit animated or flashingsigns|
|9|Move all footcandle standards into 1 central table, and make the following changes:<br>a. Split the property line footcandle limit into a non-residential and residential option<br>b. Add a maximum footcandle for illumination of vertical surfaces<br>c. Add a maximum footcandle for electronic message displays|
|10|Move all Kelvin ratings into 1 central table, and make the following changes:<br>a. Reduce the maximum kelvin rating for commercial<br>b. Create separate kelvin standards for residential and rural areas<br>c. Create a higher kelvin rating for vehicular canopies, sports fields, and performance areas<br>d. Exempt internallylit signs,lettering,and electronic displays from kelvin standards|
|11|Add agraphic showingthe difference between full cutoff,partial cutoff, and non-cutoff fixtures|
|12|Require that lighting be aimed and shielded so the direct light falls on the property of the light and not<br>onto adjacentparcels except for sharedparkingareas or common developments|
|13|Move all maximum height standards into 1 central table, and make the following changes:<br>a. Reduce the maximum height of security lighting to 15 feet<br>b. Create a 10 foot height limit for electronic message displays<br>c. Reduce the maximum height for outdoor sports courts to 50 feet<br>d. Reduce sign lighting to 20 feet<br>e. Reduce the height ofgeneral site lightingto 30 feet|
{4}------------------------------------------------
||f. Clarifyindividual lights on apartment balconies have no height limit but must be full cutoff|
|---|---|
|14|Revise accent and facade lighting to clarify that it only applies to lights which are directly facing a<br>structure or sign that is beingilluminated.|
|15|Clarifythe wordingforplacement of low wattage fixtures close to buildings.|
|16|Allow non-compliant vehicular canopies to be updated without having to meet all lighting standards by<br>removingsome of the faces of the canopylighting.|
|17|Require that dusk to dawn, security, and flood lights be motion-activated and designed to turn off<br>within 20 minutes of activation.|
|18|Require that all street lightingbe full cutoff.|
|19|Clarifythat outdoor sports fields andperformance areas must be cutoff or full cutoff light fixtures|
|20|Limit lightingof sports fields to those in open for use or undergoingmaintenance.|
|21|Create standards for electronic message displays.|
|22|Create maximum size standards for backlit signs and letters based on mountingtype/location.|
|23|Clarifythephotometricplan requirements.|
|24|Create a table identifying commercial and multi-family lighting designs which will not require a<br>photometricplan based on meetingcertain standards.|
|25|Remove the requirement for an as-built drawingfor the lighting plan.|
|26|Remove the reference to the 10 business dayreviewprocess.|



## **COMPREHENSIVE PLAN REFERENCE** 

The following sections of the Comprehensive Plan were referenced when drafting these text amendments: 

## **Growth, Equity, Conservation** 

Action 6: Support the protection of agricultural and forest lands, environmentally sensitive areas, and rural communities. 

## **Farms, Forests, Env.** 

Policy 2: Preserve Buncombe County’s natural heritage. 

Policy 3: Promote ecosystem enhancement… 

## **Health & Recreation** 

Policy 5: Utilize environmental protection and land conservation to… promote health. 

## **Infrastructure & Energy** 

Action 2: Implement policies around new development and re-development that advance decarbonization and sustainability goals 

## **CITATIONS:** 

1. Chepesiuk R. Missing the dark: health effects of light pollution. Environ Health Perspect. 2009. 

2. Nadybal SM, Collins TW, Grineski SE. Light pollution inequities in the continental United States: A distributive environmental justice analysis. Environ Res. 2020. 

3. Task Force to Study Lighting Efficiency & Light Pollution in Maryland. State of Maryland. 2002. 

4. Bartholomew, Edward & Loeffler, Mark. With Good Lighting & Justice for All. 2021. Illuminating Engineering Society. **REFERENCES:** 

- (A) Model Lighting Ordinance. 2011. International Dark Sky Association. 

- (B) Innovative Land Use Planning Techniques. A Handbook for Sustainable Dev. 2008. New Hampshire Dept. of Environmental Svcs. 

- (C) Smart Codes: Model Land-Development Regulations. 2009. American Planning Association. Planning Advisory Service report 556. 

- (D) Finding Common Ground: Answers to Common Questions about Electronic Message Centers (EMCs). International Sign Association.