{0}------------------------------------------------
**ZPH2025-00024** 

## **VERSION 1** 

## **9-15-2025** 

~~**Strikethrough**~~ **– deletions** 

**Underline - additions** 

## **Sec. 78-581. Definitions.** 

Accent lightng means an exterior light directed at and for the purpose of illuminatng an object, sign, landscaping feature, or specifc architectural detail. 

Electronic message display (EMD) means a digital surface that uses light to display informaton, graphics, or images that can be changed electronically. 

Facade lightng means the illuminaton of the vertcal surface of a building through shielded light fxtures atached to and pointng at the structure. 

## **Sec. 78-668. - Lighting standards.** 

(a) _Purpose._ Lighting standards are established in order to permit ~~,~~ reasonable uses of outdoor lighting for night-time safety, utility, security, productivity, enjoyment and commerce. These standards will minimize light pollution, light trespass, and glare, ~~and will work to~~ promote energy efficient lighting practices and systems, and reduce adverse impacts of outdoor lightng on wildlife and human health. Lightng should be used only where needed, directed and shielded, no brighter than necessary, controlled during off-hours, and of warmer colors where possible. 

(b) _Applicability._ Lighting standards shall apply to all new uses including commercial, industrial, public and residential development, all new and pre-existng dusk-to-dawn utility/security lights, and all new street lighting. To the extent i regulated by this section, all existing outdoor lights or lighting systems nstalled prior to the adoption of this section, shall be treated as nonconforming uses pursuant to secton 78-657 with the following exceptions: 

(1) When a vehicular canopy is renovated at a cost which exceeds 50 percent of the value of the structure or is replaced in its entirety, all lighting attached to the new or renovated canopy must comply with subsection (e). 

~~(2) When all the light fxtures of an assembly or group (such as, all the fxtures lightng a loading area or all the fxtures lightng one facade of a building) are replaced, the new lightng must comply with subsecton (e).~~ 

(3) All pre-existing non-cutof metal halide or high pressure sodium dusk-to-dawn utility/security lights shall conform to the provisions of subsection (e) ~~within fve years from the date this secton was adopted.~~
{1}------------------------------------------------
_Figure X: Example of a prohibited metal halide dusk-to-dawn security light._ 

(c) _Exemptions._ The following are not regulated by the lighting standards set forth in this section: 

(1) Lighting for single-family residential ~~use s~~ tructures, with the exception of dusk-to-dawn utility/security lights which shall be regulated pursuant to subsection (e) ~~(5)~~ . 

(2) Lighting required by federal, state, or local laws or regulations; 

(3) Seasonal displays using multiple low-wattage bulbs; 

(4) Lighting used during an emergency or by emergency services personnel or at their direction; 

(5) Temporary lighting which does not utilize the lighting types described in subsection (d)(1); 

(6) Temporary lighting used for public purposes including but not limited to highway construction and public utility repairs ~~.;~~ 

- (7) Low intensity ornamental gas fame lamps which include a solid cover over the top of the light source; 

(8) Low voltage (twelve volts or less), low watage ornamental landscape lightng, where fxtures are directed downward, and where any single light bulb does not exceed 25 lumens. 

(d) _Prohibitions._ The following lighting types are specifically prohibited: 

(1) Search lights, laser source lights, or any other similar high intensity lights except for those permitted in advance as required in subsection (f)(5) to be used on a temporary basis; 

(2) Lighting that is oriented upward or outward, and any light which is not a cutof or full cutof light fxture, except as otherwise provided for in this sectio ~~n:;~~ 

(3) Lighting that could be confused for a traffic control device; 

(4) A suspended string of lights, consisting of individual lamps larger than 45 lumens for LED bulbs, or 25 lumens per incandescent bulb, unless used only for temporary seasonal decorations ~~.;~~ 

(5) Animated signs which use fashing or intermitent lights, sound, color changes, video, or other means to give moton to, or bring atenton to the sign or the message on it, except that electronic message signs shall be regulated under secton (e)(12). 

## (e) _Lighting specifications._ 

- (1) _Intensity._ 

   - ~~a.       Unless otherwise specifed, the maximum light level at any point shall be 0.75 footcandles at any property line, or 3.0 footcandles at any public street right-of-way.~~ 

   - ~~b. The maximum average light level for the developed area of the project to be permited shall be 4.5 footcandles.~~ 

   - ~~c. The maximum ratng for LED lights shall be 4.300 degrees Kelvin.~~ 

      - a. _Footcandles._ Footcandle light limits shall be as follows: 

**Table X. Maximum footcandles Locaton Max. footcandle** Non-residental property lines 0.75 Residental property lines 0.5
{2}------------------------------------------------
|Public street rights-of-way|3.0|
|---|---|
|Outdoor parking, loading and storage|6.0|
|Total Developed area<br>ii|4.5 max. avg.|
|Illumination of vertical surfaces|5.0 max. avg.|
|Outdoor sales/display areas<br>i|25 max. avg.|
|Outdoor sports fields, courts, performance areas|60 fc max. avg.|
|Electronic message displays (EMD)|0.3|



i ~~.c. b~~ . _Kelvin ratng._ The maximum color temperature rating for LED lights shall be as follows: 

|**Table X. Maximum Kelvin ratings**|**Table X. Maximum Kelvin ratings**|**Table X. Maximum Kelvin ratings**|
|---|---|---|
|All lights,<br>except those<br>listed below<br>|ZONING: OU, RLD, BDM, R1, R2, R3|**i**<br>3,000 degrees kelvin|
||ZONING: NS, CS, EMP, CR, PS<br>i|4,000 degrees kelvin|
|Beneath vehicular gas station canopies, outdoor sports<br>fields and courts, and performance areas||5,000 degrees kelvin|
|i<br>Internally-lit, backlit signs/lettering, and Electronic<br>Message Displays||Exempt from Kelvin limits when light<br>source is entirely within a non-<br>transparent enclosure|



(2) _Luminaire type._ All lighting luminaires to be installed on a permanent basis shall consist of full cutoff or ~~and~~ partal cutoff fixtures, unless otherwise stipulated by this section. Full cutoff fixtures shall be ~~utlized~~ required where the luminaire has more than a 1,250 lumen output, unless as otherwise stipulated by this section. Lighting fixtures to be utilized on a temporary basis and as permitted through subsection (f)(5) shall be exempt from this requirement. 

_Figure X. Lightng fxture cutof types_ a) All light fxtures shall be aimed and shielded so that the direct illuminaton shall be confned to the property boundaries of the light source. Lightng shall not be aimed onto adjacent propertes except in cases of shared parking or for communal infrastructure of phased or common developments on adjacent parcels.
{3}------------------------------------------------
(3) _Height_ . The maximum mounted height of light fxtures above lowest adjacent grade shall be as follows: 

|||**Table X: Maximum Mounted Exterior**|**Table X: Maximum Mounted Exterior**|**Light Fixture Height**|**Light Fixture Height**|**Light Fixture Height**|**Light Fixture Height**|
|---|---|---|---|---|---|---|---|
||||**Fixture type or use**||**Maximum mounted height**|||
||Dusk-to-dawn, security, and food lights||||||15 feet|
||Electronic message displays (EMD)||||||10 feet|
||Outdoor sports courts<br>||||||50 feet|
||Outdoor sports felds and performance areas<br>||||||80 feet|
||Parking lot and street lightng<br>||||||37 feet|
||<br>|||||||
||Sign lightng||||||20 feet|
||Site lightng||Individual apartment balconies|||Must|N/A<br>be full cutof|
||||All other types||||30 feet|



~~(3)~~ (5) _Accent and facade_ lighting _._ Accent or facade lighting shall meet the following standards ~~be directed toward at the face of the building or structure.~~ 

a. Lighting fixtures shall be directed downward ~~rather than upward~~ and shall be full cutoff fixtures, or shall be fully shielded and directly facing the structure or sign surface to be illuminated. ~~The zoning administrator or the board of adjustment may waive this requirement in cases where it is impractcal.~~ 

b. ~~Placement of low watage fxtures with shields (as needed) close to the building to graze the facade is required to minimize refected light from windows and other surfaces.~~ Fixtures placed close to windows and other refectve surfaces shall be low watage and include shields to minimize refectons. Lightng of any porton of a structure with a polished or glass exterior surface is prohibited. 

## ~~(4)~~ (6) _Vehicular canopies._ 

(a) ~~A~~ reas under a vehicular canopy shall have a maximum average horizontal illuminance of 30 footcandles. All lighting under the canopy, including but not limited to, luminaires mounted on the lower surface of the canopy and auxiliary lighting within signage or panels over the pumps, is to be included in the calculation. Lighting under vehicular canopies shall be designed so as not to create glare off-site. Acceptable methods include one or more of the following: 

~~a.~~ (i) Recessed fixture incorporating a lens cover that is either recessed or flush with the bottom surface (ceiling) of the vehicular canopy that provides a full cutoff or fully shielded light distribution. 

~~b.~~ (ii) Surface mounted fixture incorporating a flat glass that provides a full cutoff or fully shielded light distribution.
{4}------------------------------------------------
- (b) When replacing the internally lit signage lightng on a vehicular canopy that is on a property that has pre-existng, non-conforming lightng, signage lightng and canopy wrap lightng shall only be - - allowed to be replaced on one street facing side of the canopy. Internally lit signage shall be removed from all other sides of the canopy unless the entre site is brought into compliance. 

~~(5)~~ (7) _Dusk-to-dawn utilit_ ~~_y/,_~~ _security, and food lights._ Dusk-to-dawn utility ~~_/,_~~ _security and food_ lights shall ~~have a maximum ratng of 9,500 lumens, shall be mounted at a maximum height of 25 feet above the lowest adjacent grade, and must b~~ e full cutoff fixtures, and must be moton-actvated and designed to turn of afer no more than 20 minutes afer actvaton. The Zoning Administrator may waive the requirement for motonactvaton in cases where the type of use requires specifc security features on the property due to a demonstrable, signifcant public health or safety interest. 

~~(6)~~ (8) _Street_ lighting _._ ~~a.~~ ~~_Alignment._ S~~ treet lighting on newly constructed streets shall be alternately staggered on each side of the street. The zoning administrator or the board of adjustment may waive this requirement in cases where it is impractical. All street lightng must consist of full cutof fxtures. 

~~_b. Intensity._ Newly installed street lightng luminaires shall meet the following standards:~~ 

~~1. Individual luminaires erected in residental areas shall have a ratng which does not exceed 9,500 lumens.~~ 

~~2. Individual luminaires erected in commercial and industrial areas shall have a ratng which does not exceed 50,000 lumens.~~ 

~~c.~~ ~~_Luminaire type._ All street lightng must consist of full cutof fxtures. If the luminaire is a post mounted decoratve fxture mounted at a height of no more than 18 feet above the lowest adjacent grade, the luminare may consist of a cutof fxture if the zoning administrator or board of adjustment determines that appropriate glare reducton measures are taken.~~ 

~~(7)~~ ~~_Outdoor parking, loading and storage areas._ The mountng height of all outdoor parking, loading and storage area lightng shall not exceed 37 feet above the lowest adjacent grade. The lightng of outdoor parking areas shall have a maximum average horizontal illuminance of 6.0 footcandles.~~ 

~~(8)~~ ~~_Outdoor sales/display areas._ The mountng height of all outdoor sales/display area lightng shall not exceed 37 feet above the lowest adjacent grade. The lightng of outdoor sales/display areas shall have a maximum average horizontal illuminance of 25 footcandles.~~ 

## ~~(9)~~ (11) 

~~a. The mountng height of outdoor sports feld and outdoor performance area lightng fxtures shall not exceed 80 feet from the lowest adjacent grade.~~ 

b. _Glare Control._ All outdoor sports field and outdoor performance area lighting fixtures shall be cutof or full cutof fxtures which are equipped with a glare control package (louvers, shields, or similar devices). The fixtures must be aimed so that their beams are directed and fall within the primary playing or performance area. 

c. _Hours of Operaton_ . The hours of operation for the lighting system shall coincide with ~~actve o~~ pen use of the field or performance area and any necessary maintenance thereof. ~~Lightng the feld or performance area during periods of vacancy shall be prohibited. O~~ nly areas which are open for use, or undergoing maintenance, shall be lit. 

(12) _Electronic message displays (EMD)_ .
{5}------------------------------------------------
(a) _Applicability._ The following standards shall apply to all electronic message displays which are visible from or adjacent to a public or private road, with the following exceptons: 

- (i) Outdoor Sports Field displays which directly face the feld or bleachers are exempt; 

- (ii) Displays located along interior development roads which are not visible outside of the development are exempt; 

- (iii) Public schools displays shall be allowed in all zoning districts; (iv) Government Protectve Service displays shall be allowed in all zoning districts, and shall be exempt from the limit on rate of change. 

(b) _Locatons:_ EMD's are prohibited in the OU, R-LD, BDM, R-1, R-2, and R-3 zoning districts. 

(c) _Dimensions_ . A maximum of one (1) electronic message sign shall be allowed per property and the electronic display shall not exceed 15 square feet in size. 

(d) _Setbacks_ . Signs shall be located no closer to the edge of the public road than 20 feet, and shall not be located within 100 feet from any intersecton. 

## (e) _Display_ . 

(i) _Rate of change_ . Displays shall be programmed to change no more than once per 12 hours; 

(ii) _Moton_ . Only statc text and imagery may be displayed on the sign, and shall not include animaton, video, fashing or intermitent lights, sound, color changes, or other means to give moton to the sign or message on it. Any change of the message shall be completed immediately without pauses and all parts of the message shall change simultaneously; 

- (iii) _Brightness_ . The maximum light level shall be 20 nits during non daylight hours, and 1,000 nits during daylight hours. Displays shall be equipped with a feature which automatcally adjusts the brightness of the display based on ambient conditons; 

(13) _Backlit signs and internally-lit signs and leters_ . Backlit signs, or groupings of backlit leters, shall not exceed the following total cumulatve size for the area of the sign that includes lightng: 

- a. Signs mounted on structures: 50 square feet of lit area 

- b. Pole-mounted or pylon signs: 15 square feet of lit area 

- c. Monument signs: 20 square feet of total lit area, or 5 square feet of lit area per business sign. 

_Figure X. Maximum backlit sign sizes._
{6}------------------------------------------------
## (f) _Administration and enforcement._ 

(1) Lighting plan required. A lighting plan designed and sealed by a licensed engineer shall be submitted with the application for a zoning certificate of compliance. The plan shall indicate the following: 

a. Location and mounted height of all exterior lighting on the property. 

b. A photometric plan containing the following: 

- ~~i)~~ A point-by-point footcandle array photometric plan, ~~in a printout format~~ indicating the location and aiming of all pre-existng and proposed illuminating devices is required for all lightng except those indicated in the table below: 

||||**Table X: Exterior Lightng Designs Which Are Exempt**|**Table X: Exterior Lightng Designs Which Are Exempt**|**Table X: Exterior Lightng Designs Which Are Exempt**|**Table X: Exterior Lightng Designs Which Are Exempt**|**Table X: Exterior Lightng Designs Which Are Exempt**|**Table X: Exterior Lightng Designs Which Are Exempt**|**Table X: Exterior Lightng Designs Which Are Exempt**|**Table X: Exterior Lightng Designs Which Are Exempt**|**Table X: Exterior Lightng Designs Which Are Exempt**|**Table X: Exterior Lightng Designs Which Are Exempt**|**from Photometric Plan Requirements**|**from Photometric Plan Requirements**|**from Photometric Plan Requirements**|**from Photometric Plan Requirements**|**from Photometric Plan Requirements**|**from Photometric Plan Requirements**|**from Photometric Plan Requirements**|**from Photometric Plan Requirements**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||**Cutof**||||||**Max. Number of**<br>**Fixtures**|||||||||**Conditons**|
||||||||||||||||||||||
||||||||||||||||||||||
|||**Type**|||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||Backlit sign||||N/A||N/A|||Up to 2|||20 feet|||5|feet||All other types of<br>lightng on the site<br>must be legally<br>conforming.||
||||||||||||||||||||||
||Wall pack||||Full<br>cutof||50 feet|||Up to 10 total wall packs<br>in the development|||20 feet|||25 feet from<br>residental<br>PL;<br>10 feet from<br>commercial<br>PL|||Located within a<br>development<br>containing no other<br>types of communal<br>lightng, except<br>backlit signs or entry<br>signs with up to 6<br>accent lights.||
||Street light||||Full<br>cutof||250 feet|||1 light per 4 subdivision<br>lots;<br>N/A to commercial<br>developments|||25 feet||||||||
||Parking lot<br>pole light||||Full<br>cutof||100 feet|||Up to 10 total parking<br>lot pole lights in the<br>development|||||||||||
||Any mix of<br>lightng types<br>listed above||||Full<br>cutof||As listed<br>above by<br>type|||Up to 10 total lights in<br>the development|||As listed<br>above by<br>type|||As listed<br>above by<br>type|||N/A||



c. The ~~printout~~ site lightng plan shall include a printed statement that the lightng plan is in compliance with the requirements of this secton. ~~indicate compliance with the lightng specifcatons required by this secton.~~ 

d. The plan shall be accompanied by a description of the illuminating devices, fixtures, lamps, supports, reflectors, poles, raised foundations and other devices including, but not limited to,
{7}------------------------------------------------
manufacturers or electric utility catalog specification sheets and/or drawings, and ~~photometric report~~ indicating fixture classification (cutoff fixture, full cutoff fixture, etc.) must be furnished. 

e. The zoning administrator may waive the requirements for a lighting plan set forth above, provided the applicant has provided all other required information and can sufficiently demonstrate compliance with this section. If the lighting plan requirements are waived, the requirements set forth in subsection (f)(2) ~~and (f)(3) s~~ hall also not apply. 

(2) A written statement signed and sealed by a licensed engineer, which indicates that the lighting plan complies with the standards set forth herein, shall be submitted with any application for a zoning certificate of compliance that proposes permanent outdoor lighting. 

~~(3) A signed and sealed as-built drawing which demonstrates that the lightng plan described in subsecton (f)(l) and submited with the zoning certfcate of compliance applicaton was followed shall be submited for review prior to the issuance of a zoning certfcate of occupancy for the project.~~ 

~~(4)~~ (3) Light measurement technique. When a lightng afdavit is allowed in lieu of a photometric plan by the Zoning Administrator, the ~~lL~~ ight level measurements of light trespass shall be made at the property line ~~of the property~~ upon which light to be measured is being generated. Measurements shall be made at finished grade (ground level) with the light registering portion of the meter held parallel to the ground pointing up. Measurements shall be taken with a light meter that has been calibrated within the previous two years. 

~~(5)~~ (4) Permit for temporary lighting required. Applicants who wish to utilize lighting on a temporary basis ~~The~~ or lighting described in subsection (d)(1) must submit a written request to the zoning administrator. ~~zoning administrator shall have ten business days to approve or deny the permit applicaton.~~ The application shall include: 

a. The purpose of the lighting; 

b. The hours of lighting operation; 

c. Where applicable, a plan showing the extent and intensity of light trespass upon adjacent properties; 

d. Signed certification that in no case shall such lighting be directed at roadways where such lighting could pose a public safety threat to vehicular traffic; and 

e. An application ~~fee f~~ or ~~the~~ a zoning certificate of compliance ~~which shall be issued by the zoning administrator.~~ 

A permit for temporary lighting, in the form of a zoning certificate of compliance, shall be issued for an operation period of no more than 30 days. Once the permit has been issued, it may be renewed in 30-day periods for up to a total of 90 days unless the permit is for lighting as described in subsection (d)(1). If operation is to continue past the close of the 90-day period, a new permit must be applied for and obtained. Temporary lighting of the type described in subsection (d)(1) shall be event-specific and shall not be permitted for a duration of more than five (5) days. In no case shall temporary lighting be permitted on a single property, in one or in multiple locations, for more than 180 days per calendar year.